MODEL 2234 DIGITAL FLOW COMPUTER ___________________________
Table 2-5. Error Code Diagnostic Chart
(Continued)
Error Code
Possible Cause
Check
Solution
23
Line 3
differential
pressure over
range
1. Pressure transducer
not used for line 3.
2. Pressure out of
range, transducer
malfunctioning or mis-
calibrated, wiring
error.
1. Check VAR value
of read code 263
(H2O).
2. Check code number
entered for CONFIG
(system configuration),
command code 5.
1. Enter new
CONFIG code
number.
1. Check wiring.
2. Verify pressure.
3. Check transducer.
24
Line 4
differential
pressure over
range
1. Pressure transducer
not used for line 4.
2. Pressure out of
range, transducer
malfunctioning or mis-
calibrated, wiring
error.
1. Check VAR value
of read code 264
(H20).
2. Check code
number entered for
CONFIG (system
configuration),
command code 5.
1. Enter new
CONFIG code
number.
1. Check wiring.
2. Verify pressure.
3. Check transfer.