VLT 5000 series
FC 302 series
Parameter 916 PCD config read
9-16 PCD Read Configu-
ration
Options
[0] None
[0] None
[538] Alarm word
[1472] VLT Alarm Word
[540] Warning word
[1473] VLT Warning Word
[541] Ext. status word
[1474] VLT Ext. status
Word
[600] Operating hours
[1500] Operating hours
[601] Running hours
[1501] Running hours
[602] kWh Counter
[1502] kWh Counter
[539] Control word
[1600] Control word
[516] Reference [Unit]
[1601] Reference [Unit]
[515] Reference %
[1602] Reference %
[534] Status word
[1603] Status word
[522] Power [kW]
[1610] Power [kW]
[523] Power [HP]
[1611] Power [HP]
[524] Motor voltage
[1612] Motor voltage
[518] Motor frequency
[1613] Motor frequency
[520] Motor current
[1614] Motor current
[557] Motor RPM
[1617] Motor speed
[526] Motor thermal
[1618] Motor thermal
[521] Torque
[1622] Torque %
[525] DC link voltage
[1630] DC link voltage
[536] Brake energy/s
[1632] Brake energy/s
[535] Brake energy/2 min [1633] Brake energy/2 min
[537] Heat sink temp.
[1634] Heat sink temp.
[527] Inverter Thermal
[1635] Inverter Thermal
[533] External reference
[1650] External reference
[532] Pulse reference
[1651] Pulse reference
[517] Feedback [Unit]
[1652] Feedback [Unit]
[528] Digital input
[1660] Digital input
[529] Analog input 53
[1662] Analog input 53
[530] Analog input 54
[1664] Analog input 54
[531] Analog input 60
[1664] Analog input 54
Table 5.291 Conversion of Parameter 916
VLT 5000 series
FC 302 series
Parameter
917 Spontaneous messages
Not converted
Table 5.292 Conversion of Parameter 917
VLT 5000 series
FC 302 series
Parameter
918 Station address
9-18 Node Address
Range
0 - 125
0 - 125
Table 5.293 Conversion of Parameter 918
VLT 5000 series
FC 302 series
Parameter
927 Parameter edit
9-27 Parameter Edit
Options
[0] Disable
[0] Disable
[1] Enable
[1] Enable
Table 5.294 Conversion of Parameter 927
VLT 5000 series
FC 302 series
Parameter
928 Control authority
9-28 Process Control
Options
[0] Disable
[0] Disable
[1] Enable
[1] Enable cyclic master
Table 5.295 Conversion of Parameter 928
VLT 5000 series
FC 302 series
Parameter 953 Warning parameter 9-53 Profibus Warning Word
Table 5.296 Conversion of Parameter 953
VLT 5000 series
FC 302 series
Parameter
964 Identification
9-64 Device Identification
Table 5.297 Conversion of Parameter 964
VLT 5000 series
FC 302 series
Parameter
965 Profile Number
9-65 Profile Number
Table 5.298 Conversion of Parameter 965
VLT 5000 series
FC 302 series
Parameter
967 Control word (FMS)
Not converted
Table 5.299 Conversion of Parameter 967
VLT 5000 series
FC 302 series
Parameter
968 Status word (FMS)
Not converted
Table 5.300 Conversion of Parameter 968
VLT 5000 series
FC 302 series
Parameter 970 Parameter set-up selection 9-70 Edit Set-up
Options
[0] Factory setting
[0] Factory setting
[1] Parameter setup 1
[1] Parameter setup 1
[2] Parameter setup 2
[2] Parameter setup 2
[3] Parameter setup 3
[3] Parameter setup 3
[4] Parameter setup 4
[4] Parameter setup 4
[5] Active setup
[9] Active setup
Table 5.301 Conversion of Parameter 970
Parameter Mapping Lists
VLT
®
AutomationDrive FC 302 PROFIBUS Converter Operating Instructions