5.8 VLT
®
5000 Parameter Group 7
VLT 5000 series
FC 302 series
Parameter 700 System control
8-02 Control Word Source
33-82 Drive Status Monitoring
Options
[0] Enable SyncPos
Par. 8-02: [5] Option C0
Par. 33-82: [1] On
[1] Disable SyncPos
Par. 8-02: [1] FC RS-485
[2] Enable SyncPos
without VLT
monitoring
Par. 8-02: [5] Option C0
Par. 33-82: [0] Off
Table 5.255 Conversion of Parameter 700
VLT 5000 series
FC 302 series
Parameter
701 Program
number
33-80 Activated
Program Number
Options
-1 – 127
-1 – 127
Table 5.256 Conversion of Parameter 701
VLT 5000 series
FC 302 series
Parameter 702 PID Proportional factor 32-60 Proportional factor
Options
0 – 65000
0 – 100000
Table 5.257 Conversion of Parameter 702
VLT 5000 series
FC 302 series
Parameter
703 PID Derivative
factor
32-61 Derivative
factor
Options
0 – 65000
0 – 100000
Table 5.258 Conversion of Parameter 703
VLT 5000 series
FC 302 series
Parameter
704 PID Integral factor
32-62 Integral factor
Options
0 – 65000
0 – 100000
Table 5.259 Conversion of Parameter 704
VLT 5000 series
FC 302 series
Parameter 705 PID Integral
bandwidth
32-63 Limit Value for
Integral Sum
Options
0 – 1000
0 – 1000
Table 5.260 Conversion of Parameter 705
VLT 5000 series
FC 302 series
Parameter 706 PID Active bandwidth
32-64 PID Bandwidth
Options
0 – 65000
0 – 1000
Table 5.261 Conversion of Parameter 706
VLT 5000 series
FC 302 series
Parameter 707 PID Velocity Feed-
forward
32-65 Velocity Feed-
Forward
Options
0 – 65000
0 – 100000
Table 5.262 Conversion of Parameter 707
VLT 5000 series
FC 302 series
Parameter 708 PID Acceleration
Feed-forward
32-66 Acceleration Feed-
Forward
Options
0 – 65000
0 – 100000
Table 5.263 Conversion of Parameter 708
VLT 5000 series
FC 302 series
Parameter 709 PID Velocity filter
33-26 Velocity Filter
Options
-500000 – 500000
-1073741824 – 107374203
Table 5.264 Conversion of Parameter 709
VLT 5000 series
FC 302 series
Parameter
710 - 779
19-10 -19-79
Options
User defined
User defined
Table 5.265 Conversion of Parameters 710 to 779
VLT 5000 series
FC 302 series
Parameter
780 Dead time compensation
Not supported
Options
[0] Off
[1] On
Table 5.266 Conversion of Parameter 780
VLT 5000 series
FC 302 series
Parameter
781 Program ID
Not supported
Options
0 – 65000
Table 5.267 Conversion of Parameter 781
VLT 5000 series
FC 302 series
Parameter 795 - 799 User defined
(read only)
19-95 -19-99 User
defined (read only)
Options
User defined
User defined
Table 5.268 Conversion of Parameters 795 to 799
Parameter Mapping Lists
VLT
®
AutomationDrive FC 302 PROFIBUS Converter Operating Instructions
38
MG34N202 - Rev. 2013-10-15
5