5.5 VLT
®
5000 Parameter Group 4
VLT 5000 series
FC 302 series
Parameter 400 Brake function/
over voltage cont.
2-10 Brake Function
2-17 Over-voltage Control
Options
[0] Off
[0] Off
[1] Resistor brake
Par. 2-10 = *1* Resistor brake
Par. 2-17 = [0] Off
[2] Over voltage
control
Par. 2-10 = [0] Off
Par. 2-17 = [2] Enabled
[3] Over voltage
control and stop
Par- 2-10 = [0] Off
Par. 2-17 = [1] Enabled (not at
stop)
Table 5.128 Conversion of Parameter 400
VLT 5000 series
FC 302 series
Parameter 401 Brake resistor, [
Ω
]
30-81 Brake Resistor (ohm)
Options
Power unit dependable Power unit dependable
Table 5.129 Conversion of Parameter 401
VLT 5000 series
FC 302 series
Parameter 402 Brake power limit,
[kW]
2-12 Brake Power Limit
(kW)
Range
Depends on unit
Depends on unit
Table 5.130 Conversion of Parameter 402
VLT 5000 series
FC 302 series
Parameter 403 Power monitoring 2-13 Brake Power Monitoring
Options
[0] Off
[0] Off
[1] Warning
[1] Warning
[2] Trip
[2] Trip
Table 5.131 Conversion of Parameter 403
VLT 5000 series
FC 302 series
Parameter
404 Brake check
2-15 Brake Check
Options
[0] Off
[0] Off
[1] Warning
[1] Warning
[2] Trip
[2] Trip
Table 5.132 Conversion of Parameter 404
VLT 5000 series
FC 302 series
Parameter
405 Reset
14-20 Reset Mode
Options
[0] Manual reset
[0] Off
[1] Automatic reset
x 1
[1] Automatic reset x
1
[2] Automatic reset
x 2
[2] Automatic reset x
2
[3] Automatic reset
x 3
[3] Automatic reset x
3
[4] Automatic reset
x 4
[4] Automatic reset x
4
[5] Automatic reset
x 5
[5] Automatic reset x
5
[6] Automatic reset
x 6
[6] Automatic reset x
6
[7] Automatic reset
x 7
[7] Automatic reset x
7
[8] Automatic reset
x 8
[8] Automatic reset x
8
[9] Automatic reset
x 9
[9] Automatic reset x
9
[10] Automatic reset
x 10
[10] Automatic reset x
10
Table 5.133 Conversion of Parameter 405
VLT 5000 series
FC 302 series
Parameter 406 Automatic restart
time
14-21 Automatic Restart
Time
Range
0 – 10 s
0 – 600 s
Table 5.134 Conversion of Parameter 406
5000 series
FC 302 series
Parameter 407 Mains failure
14-10 Mains Failure
Data range [0] No function
[0] No function
[1] Controlled ramp
down
[1] Controlled ramp down
[2] Controlled ramp
down and trip
[2] Controlled ramp down
and trip
[3] Coast
[3] Coast
[4] Kinetic back-up
[4] Kinetic back-up
[5] Controlled alarm
suppression
[5] Kinetic back-up, trip
Table 5.135 Conversion of Parameter 407
VLT 5000 series
FC 302 series
Parameter
408 Quick discharge
Not converted
Table 5.136 Conversion of Parameter 408
Parameter Mapping Lists
VLT
®
AutomationDrive FC 302 PROFIBUS Converter Operating Instructions
MG34N202 - Rev. 2013-10-15
29