VLT 5000 series
FC 302 series
Parameter
445 Flying start
1-73 Flying Start
Options
[0] Off
[0] Disable
[1] On
[1] Enable
Table 5.172 Conversion of Parameter 445
VLT 5000 series
FC 302 series
Parameter
446 Switching
pattern
14-00 Switching
Pattern
Options
[0] 60 AVM
[0] 60 AVM
[1] SFAVM
[1] SFAVM
Table 5.173 Conversion of Parameter 446
VLT 5000 series
FC 302 series
Parameter
447 Torque
compensation
Not supported
Table 5.174 Conversion of Parameter 447
VLT 5000 series
FC 302 series
Parameter
448 Gear ratio
Not supported
Table 5.175 Conversion of Parameter 448
VLT 5000 series
FC 302 series
Parameter
449 Friction loss
Not supported
Table 5.176 Conversion of Parameter 449
VLT 5000 series
FC 302 series
Parameter
450 Mains voltage
at mains fault
14-11 Mains Voltage
at Mains Fault
Range
180 – 690 V
100 – 800 V
Table 5.177 Conversion of Parameter 450
VLT 5000 series
FC 302 series
Parameter
453 Gear ratio,
speed close loop
7-07 Speed PID
Feedback Gear Ratio
Range
0.01 – 100.00
0.0001 – 32.0000
Table 5.178 Conversion of Parameter 453
VLT 5000 series
FC 302 series
Parameter
454 Dead time
compensation
Not supported
Table 5.179 Conversion of Parameter 454
VLT 5000 series
FC 302 series
Parameter
455 Frequency
range monitor
Not supported
Table 5.180 Conversion of Parameter 455
VLT 5000 series
FC 302 series
Parameter
457 Phase loss
functions
14-12 Function at
Mains Imbalance
Options
[0] Trip
[0] Trip
[1] Warning
[1] Warning
Table 5.181 Conversion of Parameter 457
VLT 5000 series
FC 302 series
Parameter
483 Dynamic DC
link compensation
Not supported
Table 5.182 Conversion of Parameter 483
Parameter Mapping Lists
VLT
®
AutomationDrive FC 302 PROFIBUS Converter Operating Instructions
MG34N202 - Rev. 2013-10-15
33