5 Parameter Mapping Lists
5.1 VLT
®
5000 Parameter Group 0
VLT 5000 series
FC 302 series
Parameter
001 Language select
0-01 Language
Options
[0] English
[0] English
[1] Deutsch
[1] Deutsch
[2] French
[2] French
[3] Dansk
[3] Dansk
[4] Spanish
[4] Spanish
[5] Italian
[5] Italian
Table 5.1 Conversion of Parameter 001
VLT 5000 series
FC 302 series
Parameter
002 Local/remote control
Not converted
Options
[0] Remote
[1] Local with External Stop
[2] Local
Table 5.2 Conversion of Parameter 002
VLT 5000 series
FC 302 series
Parameter
003 Local reference
Not converted
Table 5.3 Conversion of Parameter 003
VLT 5000 series
FC 302 series
Parameter
004 Active Set-up
0-10 Active Set-up
Options
[0] Factory Setup
[0] Factory Setup
[1] Setup 1
[1] Setup 1
[2] Setup 2
[2] Setup 2
[3] Setup 3
[3] Setup 3
[4] Setup 4
[4] Setup 4
[5] Multi Setup
[9] Multi Setup
Table 5.4 Conversion of Parameter 004
VLT 5000 series
FC 302 series
Parameter
005 Setup Copy
0-51 Set-up Copy
Options
[0] Factory Set-up
[0] Factory Set-up
[1] Setup 1
[1] Setup 1
[2] Setup 2
[2] Setup 2
[3] Setup 3
[3] Setup 3
[4] Setup 4
[4] Setup 4
[5] Active Setup
[9] Active Setup
Table 5.5 Conversion of Parameter 005
VLT 5000 series
FC 302 series
Parameter
006 Setup Copy
0-51 Set-up Copy
Options
[0] No Copy
[0] No Copy
[1]
[1]
[2]
[2]
[3]
[3]
[4]
[4]
Table 5.6 Conversion of Parameter 006
VLT 5000 series
FC 302 series
Parameter
007 LCP Copy
Not converted
Table 5.7 Conversion of Parameter 007
VLT 5000 series
FC 302 series
Parameter 008 Display scaling of motor
frequency
Not converted
Table 5.8 Conversion of Parameter 008
VLT 5000 series
FC 302 series
Parameter
number
009 Display line
0-23
Parameter
number
010 Display line
0-20
Parameter
number
011 Display line
0-21
Parameter
number
012 Display line
0-22
Options
[0] None
[0] None
[1] Reference %
[1602] Reference %
[2] Reference [Unit]
[1601] Reference
[Unit]
[3] Feedback [Unit]
[1652] Feedback
[Unit]
[4] Frequency [Hz]
[1613] Frequency [Hz]
[5] Frequency x scale
[1609] Custom
readout
[6] Motor current [A]
[1614] Motor current
[A]
[7] Torque [%]
[1622] Torque [%]
[8] Power [kW]
[1610] Power [kW]
[9] Power [HP]
[1611] Power [HP]
[10] Output energy
[kWh]
[1502] kWh counter
[kWh]
[11] Motor voltage [V]
[1612] Motor voltage
[V]
Table 5.9 Conversion of Parameters 009 to 012
Parameter Mapping Lists
VLT
®
AutomationDrive FC 302 PROFIBUS Converter Operating Instructions
12