background image

MAKING MODERN LIVING POSSIBLE

Operating Instructions

VLT

®

 PROFIBUS Converter MCA 114

VLT

®

 AutomationDrive FC 302 • VLT

®

 5000

www.danfoss.com/drives

Summary of Contents for VLT series

Page 1: ...MAKING MODERN LIVING POSSIBLE Operating Instructions VLT PROFIBUS Converter MCA 114 VLT AutomationDrive FC 302 VLT 5000 www danfoss com drives...

Page 2: ......

Page 3: ...ardware Switches 9 4 1 2 Setting the PROFIBUS Address via 9 18 Node Address 9 4 1 3 Commissioning 10 4 2 LED Behaviour 10 4 3 Initialisation 11 5 Parameter Mapping Lists 12 5 1 VLT 5000 Parameter Grou...

Page 4: ...Index 44 Contents VLT AutomationDrive FC 302 PROFIBUS Converter Operating Instructions 2 MG34N202 Rev 2013 10 15...

Page 5: ...VLT 5000 is automatically linked to the corresponding ramp up time parameter in VLT Automa tionDrive FC 302 NOTICE Some parameters in the VLT 5000 are not supported in the FC 302 and some FC 302 param...

Page 6: ...ital input 27 Digital input 27 Digital input 29 Digital input 29 Digital input 32 Digital input 32 Digital input 33 Digital input 33 Digital input 20 GND Digital input 20 GND Digital input 53 Analog i...

Page 7: ...hanges made with running motor ensure that FC 302 setups are linked This is done in 0 12 This Set up Linked to 1 4 Abbreviations AOC Application oriented control CTW Control word EMC Electromagnetic C...

Page 8: ...e mains supply has been disconnected and that the necessary time has passed before removing motor and mains plugs see Discharge Time Table 7 The frequency converter has more voltage inputs than L1 L2...

Page 9: ...s connector Unlike the VLT 5000 the FC 302 Profibus connectors are colour coded to avoid swapping the bus wires Illustration 3 1 Connecting Bus Wires to VLT PROFIBUS Converter MCA 114 Profibus B 62 Rx...

Page 10: ...adapter plates are available Ordering number Style Height mm Width mm Type 130B0183 Bookstyle IP20 395 90 5001 5003 200 240 V 5001 5005 380 500 V 130B0184 Bookstyle IP20 395 130 5004 5006 200 240 V 5...

Page 11: ...Node Address Using the hardware switches select an address range from 0 to 125 factory setting 127 according to Illustration 4 1 ON 1 OFF 0 MCA 114 Profibus Converter MS NS Option A 130B1246 NS MS ON...

Page 12: ...erising Green Long green flash Baud rate found waiting for parameters from the master Red Long red flash Wrong parameters from the master Wait Configuration Green Short green flash Parameters from mas...

Page 13: ...arning Feedback High 4000000 6 10 Terminal 53 Low Voltage 0 00 Volt 6 20 Terminal 54 Low Voltage 0 00 Volt 6 22 Terminal 54 Low Current 0 00 Volt 5 51 Term 29 High Frequency 5000 Hz 5 56 Term 33 High...

Page 14: ...up 4 4 Setup 4 5 Active Setup 9 Active Setup Table 5 5 Conversion of Parameter 005 VLT 5000 series FC 302 series Parameter 006 Setup Copy 0 51 Set up Copy Options 0 No Copy 0 No Copy 1 1 2 2 3 3 4 4 T...

Page 15: ...0 series FC 302 series Parameter 013 Local Ctrl config Not converted Table 5 11 Conversion of Parameter 013 VLT 5000 series FC 302 series Parameter 014 Local Stop key 0 41 Off Key on LCP Options 0 Dis...

Page 16: ...9 Conversion of Parameter 100 VLT 5000 series FC 302 series Parameter 101 Torque charac teristic 1 03 Torque Characteristics 1 04 Overload Mode 14 40 VT Level Options 1 High constant torque Par 1 03 0...

Page 17: ...00 Volt 50 1000 V Table 5 23 Conversion of Parameter 103 VLT 5000 series FC 302 series Parameter 104 Motor frequency 1 23 Motor Frequency Range 20 1000 Hz 20 1000 Hz Table 5 24 Conversion of Parameter...

Page 18: ...C hold in start delay time 0 DC hold delay time 1 DC brake in start delay time 1 DC Brake delay time 2 Coasting in start delay time 2 Coast delay time 3 Start frequency voltage clockwise 3 Start speed...

Page 19: ...3 9 ETR warning 4 9 ETR warning 4 10 ETR trip 4 10 ETR trip 4 Table 5 47 Conversion of Parameter 128 VLT 5000 series FC 302 series Parameter 129 External motor fan 1 91 Motor External Fan Options 0 N...

Page 20: ...Minimum reference 3 02 Minimum Reference Range 100 000 000 par 205 Refmax 100 000 000 par 3 03 Refmax Table 5 56 Conversion of Parameter 204 VLT 5000 series FC 302 series Parameter 205 Maximum refere...

Page 21: ...Range 0 05 3600 00 s 0 01 3600 00 s Table 5 64 Conversion of Parameter 211 VLT 5000 series FC 302 series Parameter 212 Quick stop ramp time 3 81 Quick Stop Ramp Time Range 0 05 3600 00 s 0 01 3600 00...

Page 22: ...228 999 999 999 par 4 57 Table 5 79 Conversion of Parameter 227 VLT 5000 series FC 302 series Parameter 228 Warning High Feedback 4 57 Warning Feedback High Range par 227 100 000 000 Par 4 56 999 999...

Page 23: ...down 10 Choice of setup msb 24 Setup select bit 1 11 Slow down 29 Slow down 12 Ramp 2 34 Ramp bit 0 13 Mains failure inverted Not supported 23 Pulse reference 32 Pulse input 24 Safety interlock Not su...

Page 24: ...reset reference bit 0 7 Freeze reference 19 Freeze reference 8 Freeze output 20 Freeze output 9 Speed up 21 Speed up 10 Choice of Setup lsb 23 Setup select bit 0 11 Choice of Setup msb Speed up Not su...

Page 25: ...oltage Range 0 10 0 Volt Par 6 10 10 00 Volt Table 5 97 Conversion of Parameter 310 VLT 5000 series FC 302 series Parameter 311 Terminal 54 Analogue Input Voltage 3 16 Reference Resource 2 7 00 Speed...

Page 26: ...s FC 302 series Parameter 318 Function after time out 6 01 Live Zero Timeout Function Options 0 Off 0 Off 1 Freeze output frequency 1 Freeze output frequency 2 Stop 2 Stop 3 Jogging 3 Jog 4 Max Speed...

Page 27: ...ersion of Parameters 319 to 321 VLT 5000 series FC 302 series Parameter 319 Terminal 42 Output Digital Par 5 32 DO X30 7 MCB 101 Analogue values Par 6 50 AO 42 Pulse Par 5 66 DO X30 6 Parameter 321 Te...

Page 28: ...000 57 0 P nom 0 20 mA Par 6 50 106 Power related to norm 0 20 mA 58 0 P nom 4 20 mA Par 6 50 136 Power related to norm 4 20 mA 59 0 P nom 0 32000 p Par 5 66 106 Power related to norm 0 32000p Par 5 6...

Page 29: ...ion Relay Range 22 Ready no thermal warning Par 5 40 12 Ready no thermal W 23 Ready remote control no thermal warning Par 5 40 23 Remote ready no TW 24 Ready mains voltage within range Par 5 40 24 Rea...

Page 30: ...x speed 5 Max speed 5 Stop and trip 11 Stop and trip 7 Select setup 4 10 Select setup 4 Table 5 122 Conversion of Parameter 346 VLT 5000 series FC 302 series Parameter 357 Term 42 Output min scale 6 5...

Page 31: ...2 series Parameter 405 Reset 14 20 Reset Mode Options 0 Manual reset 0 Off 1 Automatic reset x 1 1 Automatic reset x 1 2 Automatic reset x 2 2 Automatic reset x 2 3 Automatic reset x 3 3 Automatic res...

Page 32: ...Parameter 413 Overmodulation function 14 03 Overmodulation function Options 0 Off 0 Off 1 On 1 On Table 5 141 Conversion of Parameter 413 VLT 5000 series FC 302 series Parameter 414 Minimum feedback N...

Page 33: ...FC 302 series Parameter 421 Speed PID low pass filter 7 06 Speed PID Lowpass Filter Time Data range 5 0 200 0 ms 1 0 100 0 Table 5 150 Conversion of Parameter 421 VLT 5000 series FC 302 series Paramet...

Page 34: ...e 5 164 Conversion of Parameter 437 VLT 5000 series FC 302 series Parameter 438 Process PID Anti windup 7 31 Process PID Anti Windup Options 0 Off 0 Off 1 On 1 On Table 5 165 Conversion of Parameter 4...

Page 35: ...Voltage at Mains Fault Range 180 690 V 100 800 V Table 5 177 Conversion of Parameter 450 VLT 5000 series FC 302 series Parameter 453 Gear ratio speed close loop 7 07 Speed PID Feedback Gear Ratio Ran...

Page 36: ...series FC 302 series Parameter 513 Bus time interval Not Converted Table 5 189 Conversion of Parameter 513 VLT 5000 series FC 302 series Parameter 514 Bus time interval function Not Converted Table 5...

Page 37: ...ord Table 5 210 Conversion of Parameter 534 VLT 5000 series FC 302 series Parameter 535 Brake power 2 min 16 33 Brake Energy 2 min Table 5 211 Conversion of Parameter 535 VLT 5000 series FC 302 series...

Page 38: ...s Parameter 610 Data log Feedback Not converted Table 5 233 Conversion of Parameter 610 VLT 5000 series FC 302 series Parameter 611 Data log Motor frequency Not converted Table 5 234 Conversion of Par...

Page 39: ...24 VLT 5000 series FC 302 series Parameter 625 Name plate LCP ID no Not converted Table 5 248 Conversion of Parameter 625 VLT 5000 series FC 302 series Parameter 626 Name plate Data base ID Not conver...

Page 40: ...s FC 302 series Parameter 706 PID Active bandwidth 32 64 PID Bandwidth Options 0 65000 0 1000 Table 5 261 Conversion of Parameter 706 VLT 5000 series FC 302 series Parameter 707 PID Velocity Feed forw...

Page 41: ...Stop and trip 6 No com option control Par 802 to RS485 7 Select set up 4 10 Select set up 4 Table 5 273 Conversion of Parameter 804 VLT 5000 series FC 302 series Parameter 805 Function of control word...

Page 42: ...er 911 VLT 5000 series FC 302 series Parameter 913 Broadcast index Not converted Table 5 288 Conversion of Parameter 913 VLT 5000 series FC 302 series Parameter 914 Broadcast off set Not converted Tab...

Page 43: ...eter 917 VLT 5000 series FC 302 series Parameter 918 Station address 9 18 Node Address Range 0 125 0 125 Table 5 293 Conversion of Parameter 918 VLT 5000 series FC 302 series Parameter 927 Parameter e...

Page 44: ...etups 2 Save edit setup 1 Store all setups 3 Save all setups 1 Store all setups Table 5 302 Conversion of Parameter 971 VLT 5000 series FC 302 series Parameter 980 981 982 990 Modified parameters Not...

Page 45: ...no master has been detected the parameter displays No baud rate found Check 9 53 Profibus Warning Word Bit Warn Word Hex Description 0 0001 Connection with DP master is not OK 1 0002 Unused 2 0004 FD...

Page 46: ...age 6 I Installation 7 L LEDs 10 Linked Set ups 5 Literature 3 M MCA 114 43 Mechanical Installation 8 N Node address 9 O Overview technical 3 P Parameter mapping list 12 Performance 5 Power size 3 T T...

Page 47: ...Index VLT AutomationDrive FC 302 PROFIBUS Converter Operating Instructions MG34N202 Rev 2013 10 15 45...

Page 48: ...www danfoss com drives MG34N202 130R0371 MG34N202 Rev 2013 10 15...

Reviews: