7.2.9 Soft Charge (SC) Resistors D1/D3 Units
1.
Remove the capacitor bank per instructions.
2.
Remove the input terminal mounting plate per instructions.
3.
Note the color coding for each of three wires attached to terminal 1 for each SCR/diode
module. Ensure that the correct wire is attached to the applicable stud during reassembly.
Remove the wiring from the studs. Remove the retaining screw (T25) from terminal 1 of
each of 3 SCR/diode modules and remove the bus bar.
CONTINUED ON NEXT PAGE
130BX87.10
1
2
3
Figure 7.8: D2/D4 Soft Charge Resistor (1 of 3)
380–480/500V: Clear wire leads.
525–690 V: Black wire leads.
1
Soft charge resistor
2
Bus bar BB2 (Step 3)
3
Retaining screw (Step 3)