3.1.3 Indicator Lamps
At the bottom of the control panel are a red alarm lamp, a yellow warning
lamp and a green voltage indicator lamp.
If certain threshold values are exceeded, the alarm and/or warning lamp
are activated, while a status or alarm text is shown on the display.
NB!
The voltage indicator lamp is activated when voltage
is connected to the frequency converter.
3.1.4 Local Control
[STOP/RESET]
is used for stopping the motor connected or for resetting
the frequency converter after a drop-out (trip). Can be set to active or
inactive via parameter 014
Local stop
.
If stop is activated Display line 2 will flash.
NB!
If an external stop function is not selected and the
[STOP/RESET] key is set to inactive, the motor can
only be stopped by disconnecting the voltage to the
motor or the frequency converter.
[JOG]
changes the output frequency to a preset frequency while the key
is held down. Can be set to active or inactive via parameter 015
Local
jog
.
[FWD / REV]
changes the direction of rotation of the motor, which is
indicated by means of the arrow on the display. Can be set to active or
inactive via parameter 016
Local reversing
. The [FWD/REV] key is only
active when parameter 002
Local/remote operation
is set to
Local con-
trol
.
[START]
is used to start the frequency converter. Is always active, but
cannot override a stop command.
NB!
If the local control keys are set to inactive, these will
both become active when the frequency converter is
set to
Local control
and
Remote control
via parameter
002
Local/remote operation
, with the exception of
[FWD/REV], which is only active in Local control.
3 Programming
VLT® Decentral FCD
32
MG.04.B8.02 - VLT is a registered Danfoss trademark
3