2.5.14 Connection of Sensors to M12 Plugs for T63 and T73
For rating specifications see
General technical data
, digital inputs terminals 18, 19, 29, 33.
Terminals 203/204 are used for sensor supply.
Terminal 203 = common
Terminal 204 = +24 V
Terminals 201/202 can be used for a separate 24 V supply.
2.5.15 Electrical Installation, Control Terminals
See section entitled
Earthing of screened/armoured control cables
in the Design Guide for the correct termination of control cables.
No.
Function
01-03
Relay outputs 01-03 can be used for indicating status and alarms/warnings.
12
24 V DC voltage supply.
18-33
Digital inputs.
20, 55
Common frame for input and output terminals. Can be separated with switch S100
31a, 31b
Motor thermistor
35
Common (-) for external 24 V control back up supply. Optional.
36
Ex 24 V control back up supply. Optional.
42
Analog output for displaying frequency, reference, current or torque.
46
Digital output for displaying status,warnings or alarms, as well as frequency output.
50
+10 V DC supply voltage for potentiometer
53
Analogue voltage input 0 - +/- 10 V DC.
60
Analogue current input 0/4 - 20 mA.
67
+ 5 V DC supply voltage to Profibus.
68, 69
Fieldbus serial communication*
70
Ground for terminals 67, 68 and 69.
Normally this terminal is not to be used.
D
For future use
V
+5V, red
P
RS485(+), LCP2/PC, yellow
N
RS485(-), LCP2/PC, green
G
OV, blue
* See
VLT 2800/FCM 300/FCD 300 Profibus DP V1 Operating Instructions
(MG.90.AX.YY),
VLT 2800/FCD 300 DeviceNet Operating Instructions
(MG.
90.BX.YY) or
FCD 300 AS-interface Operating Instructions
(MG.04.EX.YY).