5 How to Install
5.1 Mechanical Dimensions
5.1.1 Dimensions
A
a
b
B
C
0 D
130BB614.10
e
f
a
d
e
130BC205.10
e
f
a
e
130BC246.10
Enclosure
Power [kW(hp)]
Height [mm(in)]
Width [mm(in)]
Depth
[mm(in)]
Mounting hole [mm(in] Max.
weight
Size IP class 3x200–240
V
3x380–480
V
A
A
1)
a
B
b
C
d
e
f
kg(lb)
H3
IP20
3.7 (5)
5.5–7.5
(7.5–10)
255
(10.0)
329 (13.0)
240 (9.4)
100
(3.9)
74 (2.9) 206 (8.1)
11
(0.43)
5.5
(0.22)
8.1
(0.32)
4.5
(9.9)
H4
IP20
5.5–7.5
(7.5–10)
11–15 (15–
20)
296
(11.7)
359 (14.1)
275
(10.8)
135
(5.3)
105
(4.1)
241 (9.5)
12.6
(0.50)
7
(0.28)
8.4
(0.33)
7.9
(17.4)
H5
IP20
11 (15)
18.5–22
(25–30)
334
(13.1)
402 (15.8)
314
(12.4)
150
(5.9)
120
(4.7)
255 (10)
12.6
(0.50)
7
(0.28)
8.5
(0.33)
9.5
(20.9)
1) Including decoupling plate
Table 5.1 Dimensions, Enclosure Sizes
NOTICE
The dimensions are only for the physical units. When installing in an application, allow space above and below the units
for cooling. The amount of space for free air passage is listed in
5.1.2 Shipping Dimensions
Enclosure size
mains voltage
H3
H4
H5
200–240 V AC [kW(hp)]
3.7 (5)
5.5–7.5 (7.5–10)
11 (15)
380–480 V AC [kW(hp)]
5.5–7.5 (7.5–10)
11–15 (15–20)
18.5–22 (25–30)
IP protection rating
Maximum weight [kg(lb)]
4.5 (9.9)
7.9 (17.4)
9.5 (20.9)
Shipping dimensions
Height [mm(in)]
330 (13.0)
380 (15.0)
420 (16.5)
Width [mm(in)]
188 (7.4)
250 (9.8)
290 (11.4)
Depth [mm(in)]
282 (11.1)
375 (14.8)
375 (14.8)
Table 5.2 Shipping Dimensions
How to Install
Design Guide
MG18N202
Danfoss A/S © 12/2015 All rights reserved.
29
5
5