LCP kit, IP21
Panel mounting kit including graphical LCP, fasteners, 3 m (9 ft) cable
and gasket.
130B1113
LCP kit, IP21
Panel mounting kit including numerical LCP, fasteners and gasket.
130B1114
LCP kit, IP21
Panel mounting kit for all LCPs including fasteners, 3 m (9 ft) cable
and gasket.
130B1117
External options
EtherNet/IP
Ethernet master.
175N2584
Table 13.11 Kits Available for Enclosures D1h–D8h
13.2.7 Ordering Numbers for E1h–E4h Kits
Type
Description
Ordering number
Miscellaneous hardware
PROFIBUS top entry, E1h–E4h
Top entry for enclosure protection rating IP54.
176F1742
USB in the door, E1h–E4h
USB extension cord kit to allow access to the drive controls via laptop
computer without opening the drive.
130B1156
Ground bar
More grounding points for E1h and E2h drives.
176F6609
Mains shield, E1h
Shielding (cover) mounted in front of the power terminals to protect
from accidental contact.
176F6619
Mains shield, E2h
Shielding (cover) mounted in front of the power terminals to protect
from accidental contact.
176F6620
Terminal blocks
Screw terminal blocks for replacing spring loaded terminals.
(1 pc 10 pin 1 pc 6 pin and 1 pc 3-pin connectors)
130B1116
Back-channel cooling kits
Standard
Stainless steel
In bottom/out top, E3h
Allows the cooling air to be directed in through the bottom and out
through the top of the drive. This kit is used only for enclosure E3h
with the 600 mm (21.6 in) base plate.
176F6606
–
In bottom/out top, E3h
Allows the cooling air to be directed in through the bottom and out
through the top of the drive. This kit used only for enclosure E3h with
800 mm (31.5 in) base plate.
176F6607
–
In bottom/out top, E4h
Allows the cooling air to be directed in through the bottom and out
through the top of the drive. This kit is used only for enclosure E4h
with the 800 mm (31.5 in) base plate.
176F6608
–
In back/out back, E1h
Allows the cooling air to be directed in and out through the back of
the drive. This kit is used only for enclosure E1h.
176F6617
–
In back/out back, E2h
Allows the cooling air to be directed in and out through the back of
the drive. This kit is used only for enclosure E2h.
176F6618
–
In back/out back, E3h
Allows the cooling air to be directed in and out through the back of
the drive. This kit is used only for enclosure E3h.
176F6610
–
In back/out back, E4h
Allows the cooling air to be directed in and out through the back of
the drive. This kit is used only for enclosure E4h.
176F6611
–
In bottom/out back, E3h
Allows the cooling air to be directed in through the bottom and out
through the back of the drive. This kit is used only for enclosure E3h
with the 600 mm (21.6 in) base plate.
176F6612
–
In bottom/out back, E3h
Allows the cooling air to be directed in through the bottom and out
through the back of the drive. This kit used only for enclosure E3h
with the 800 mm (31.5 in) base plate.
176F6613
–
In bottom/out back, E4h
Allows the cooling air to be directed in through the bottom and out
through the back of the drive. This kit is used only for enclosure E4h
with 800 mm (31.5 in) base plate.
176F6614
–
In back/out top, E3h
Allows the cooling air to be directed in through the back and out
through the top of the drive. This kit is used only for enclosure E3h.
176F6615
–
In back/out top, E4h
Allows the cooling air to be directed in through the back and out
through the top of the drive. This kit is used only for enclosure E4h.
176F6616
–
How to Order a Drive
Design Guide
MG38C202
Danfoss A/S © 01/2018 All rights reserved.
199