Mains Supply 525-690 V AC
FC 302
P630
P710
P800
High/ Normal Load*
HO
NO
HO
NO
HO
NO
Typical Shaft output at 550 V [kW]
500
560
560
670
670
750
Typical Shaft output at 575 V [hp]
650
750
750
950
950
1050
Typical Shaft output at 690 V [kW]
630
710
710
800
800
900
Enclosure IP21, 54 without/ with options
cabinet
F1/ F3
F1/ F3
F1/ F3
Output current
Continuous
(at 550 V) [A]
659
763
763
889
889
988
Intermittent (60 sec overload)
(at 550 V) [A]
989
839
1145
978
1334
1087
Continuous
(at 575/690 V) [A]
630
730
730
850
850
945
Intermittent (60 sec overload)
(at 575/690 V) [A]
945
803
1095
935
1275
1040
Continuous KVA
(at 550 V) [KVA]
628
727
727
847
847
941
Continuous KVA
(at 575 V) [KVA]
627
727
727
847
847
941
Continuous KVA
(at 690 V) [KVA]
753
872
872
1016
1016
1129
Max. input current
Continuous
(at 550 V ) [A]
642
743
743
866
866
962
Continuous
(at 575 V) [A]
613
711
711
828
828
920
Continuous
(at 690 V) [A]
613
711
711
828
828
920
Max. cable size, motor [mm
2
(AWG
2)
)]
8x150
(8x300 mcm)
Max. cable size,mains F1 [mm
2
(AWG
2)
)]
8x240
(8x500 mcm)
Max. cable size,mains F3 [mm
2
(AWG
2)
)]
8x456
(8x900 mcm)
Max. cable size, loadsharing [mm
2
(AWG
2)
)]
4x120
(4x250 mcm)
Max. cable size, brake [mm
2
(AWG
2)
)
4x185
(4x350 mcm)
Max. external mains fuses [A]
1
1600
Estimated power loss, 600 V [W]
4)
7586
8933
8683
10310
10298
11692
Estimated power loss, 690 V [W]
4)
7826
9212
8983
10659
10646
12080
F3/F4 Max added losses CB or Disconnect
& Contactor
342
427
419
532
519
615
Max panel options losses
400
Weight,
enclosure IP21, IP54 [kg]
1004/ 1299
1004/ 1299
1004/ 1299
Weight, Rectifier Module [kg]
102
102
102
Weight, Inverter Module [kg]
102
102
136
Efficiency
4)
0.98
Output frequency
0-500 Hz
Heatsink overtemp. trip
95 °C
105 °C
95 °C
Power card ambient trip
75 °C
* High overload = 160% torque during 60 s., Normal overload = 110% torque during 60 s.
Table 5.8
General Specifications
VLT
®
Automation Drive FC 300 Operating Instructions
102
MG33U402 - Rev. 2013-12-16
5
5
Summary of Contents for VLT AutomationDrive FC 302