![background image](http://html1.mh-extra.com/html/danfoss/vlt-automationdrive-fc-301/vlt-automationdrive-fc-301_instruction-manual_3430507065.webp)
Type designation
P30K
P37K
P45K
P55K
P75K
High/Normal overload
1)
HO
NO
HO
NO
HO
NO
HO
NO
HO
NO
Typical shaft output at 550 V (hp [kW])
30 [22] 40 [30] 40 [30] 50 [37] 50 [37] 60 [45] 60 [45] 75 [55] 65 [50] 100 [75]
Typical Shaft output at 690 V (hp [kW])
40 [30] 50 [37] 50 [37] 60 [45] 60 [45] 75 [55] 75 [55] 100 [75] 100 [75] 125 [90]
Enclosure protection rating IP20
B4
C3
C3
D3h
D3h
Enclosure protection rating IP21, IP55
C2
C2
C2
C2
C2
Output current
Continuous (525–550 V) [A]
36.0
43.0
43.0
54.0
54.0
65.0
65.0
87.0
87.0
105
Intermittent (60 s overload) (525–550 V)
[A]
54.0
47.3
64.5
59.4
81.0
71.5
97.5
95.7
130.5
115.5
Continuous (551–690 V) [A]
34.0
41.0
41.0
52.0
52.0
62.0
62.0
83.0
83.0
100
Intermittent (60 s overload) (551–690 V)
[A]
51.0
45.1
61.5
57.2
78.0
68.2
93.0
91.3
124.5
110
continuous KVA (at 550 V) [KVA]
34.3
41.0
41.0
51.4
51.4
61.9
61.9
82.9
82.9
100
continuous KVA (at 690 V) [KVA]
40.6
49.0
49.0
62.1
62.1
74.1
74.1
99.2
99.2
119.5
Maximum input current
Continuous (at 550 V) [A]
36.0
49.0
49.0
59.0
59.0
71.0
71.0
87.0
87.0
99.0
Intermittent (60 s overload) (at 550 V) [A]
54.0
53.9
72.0
64.9
87.0
78.1
105.0
95.7
129
108.9
Continuous (at 690 V) [A]
36.0
48.0
48.0
58.0
58.0
70.0
70.0
86.0
-
-
Intermittent (60 s overload) (at 690 V) [A]
54.0
52.8
72.0
63.8
87.0
77.0
105
94.6
-
-
Additional specifications
Maximum cable cross-section for line
power and motor [mm
2
] ([AWG])
150 (300 MCM)
Maximum cable cross-section for load
share and brake [mm
2
] ([AWG])
95 (3/0)
Maximum cable cross-section
2)
for line
power disconnect [mm
2
] ([AWG])
95, 70, 70
(3/0, 2/0, 2/0)
185, 150, 120
(350 MCM,
300 MCM, 4/0)
-
Estimated power loss
at rated maximum load (hp [W])
3)
0.805
[600]
0.992
[740]
0.992
[740]
1.207
[900]
1.207
[900]
1.475
[1100]
1.475
[1100]
2.012
[1500]
2.012
[1500]
2.414
[1800]
Efficiency
4)
0.98
0.98
0.98
0.98
0.98
Table 8.12 B4, C2, C3 Enclosure, Line Power Supply 525–690 V IP20/IP21/IP55 - Chassis/NEMA1/NEMA 12 (FC 302 only), P30K-P75K
For fuse ratings, see chapter 8.7 Fuses and Circuit Breakers.
1) High overload=150% or 160% torque for a duration of 60 s. Normal overload=110% torque for a duration of 60 s.
2) The three values for the maximum cable cross-section are for single core, flexible wire and flexible wire with sleeve, respectively.
3) Applies for dimensioning of adjustable frequency drive cooling. If the switching frequency is higher than the default setting, the power losses
may increase. LCP and typical control card power consumptions are included. For power loss data according to EN 50598-2, refer to
www.danfoss.com/vltenergyefficiency
4) Efficiency measured at nominal current. For energy efficiency class, see chapter 8.4 Ambient Conditions. For part load losses, see
www.danfoss.com/vltenergyefficiency.
Specifications
Instruction Manual
MG33AP22
Danfoss A/S © Rev. 09/2014 All rights reserved.
63
8
8