Start (18)
Freeze ref (27)
Speed up (29 )
Speed down (32 )
Speed
Reference
130BB840.11
Figure 6.1 Speed Up/Down
6.1.3 Start/Stop
Parameters
FC
+24 V
+24 V
D IN
D IN
D IN
COM
D IN
D IN
D IN
D IN
+10
A IN
A IN
COM
A OUT
COM
12
13
18
19
20
27
29
32
33
37
50
53
54
55
42
39
130BB802.10
Function
Setting
5-10 Terminal 18
Digital Input
[8] Start*
5-12 Terminal 27
Digital Input
[0] No
operation
5-19 Terminal 37
Safe Stop
[1] Safe Stop
Alarm
* = Default Value
Notes/comments:
If
5-12 Terminal 27 Digital Input
is set to
[0] No operation
, a
jumper wire to terminal 27 is
not needed.
D IN 37 is an option.
Table 6.7 Start/Stop Command with Safe Stop Option
130BB805.11
Speed
Start (18)
Figure 6.2 Start/Stop Command with Safe Stop
Parameters
FC
+24 V
+24 V
D IN
D IN
D IN
COM
D IN
D IN
D IN
D IN
+10 V
A IN
A IN
COM
A OUT
COM
12
13
18
19
20
27
29
32
33
37
50
53
54
55
42
39
130BB803.10
Function
Setting
5-10 Terminal 18
Digital Input
[9] Latched
Start
5-12 Terminal 27
Digital Input
[6] Stop
Inverse
* = Default Value
Notes/comments:
If
5-12 Terminal 27 Digital Input
is set to
[0] No operation
, a
jumper wire to terminal 27 is
not needed.
D IN 37 is an option.
Table 6.8 Pulse Start/Stop
Speed
130BB806.10
Latched Start (18)
Stop Inverse (27)
Figure 6.3 Latched Start/Stop Inverse
Application Set-up Examples
Instruction Manual
34
Danfoss A/S © Rev. 09/2014 All rights reserved.
MG33AP22
6