![Danfoss VLT Automation Drive FC 300 Operating Instructions Manual Download Page 95](http://html1.mh-extra.com/html/danfoss/vlt-automation-drive-fc-300/vlt-automation-drive-fc-300_operating-instructions-manual_3441740095.webp)
Pa
r. No. #
Pa
ra
m
eter descri
pti
on
Defa
ult value
4-
set-
up
FC 3
02
on
ly
Chan
ge duri
ng op-
er
at
io
n
Co
nver-
sion in
dex
Type
14-0
*
In
ve
rt
er
Swit
ch
in
g
14-
00
Sw
itc
hi
ng
P
att
er
n
[1] S
FA
VM
Al
l set-
ups
TRUE
-
Ui
nt
8
14-
01
Sw
itchi
ng
Freq
uen
cy
nu
ll
Al
l set-ups
TRU
E
-
Ui
nt8
14-
03
Overmo
du
latio
n
[1] On
Al
l se
t-up
s
FALSE
-
U
in
t8
14-
04
PW
M R
and
om
[0
] O
ff
Al
l set-ups
TRU
E
-
Ui
nt8
14-1
*
M
ain
s On
/Off
14-
10
M
ain
s F
ail
ur
e
[0
] N
o fu
nc
tio
n
Al
l set-ups
FALSE
-
Ui
nt8
14-
11
Mai
ns V
oltage
at M
ai
ns Fault
Exp
ressio
nLimit
All set-
ups
TRUE
0
Uint16
14-
12
Fu
ncti
on
a
t Mains Imba
la
nce
[0] Tri
p
Al
l set-ups
TRU
E
-
Ui
nt8
14-2
*
T
ri
p
Rese
t
14-
20
Re
se
t M
od
e
[0] Manual re
set
Al
l set-ups
TRU
E
-
Ui
nt8
14-
21
Au
to
mat
ic Re
start Tim
e
10
s
Al
l se
t-up
s
TR
U
E
0
Ui
nt16
14-
22
Op
era
tio
n Mo
de
[0
] No
rmal
op
erat
io
n
Al
l set-ups
TRU
E
-
Ui
nt8
14-
23
Typ
eco
de
Setti
ng
nu
ll
2
se
t-
ups
FALSE
-
U
in
t8
14-
25
Tr
ip Dela
y at
To
rq
ue
L
im
it
60
s
Al
l set-ups
TRU
E
0
Ui
nt8
14
-2
6
Tr
ip Dela
y
at
I
nve
rt
er
F
au
lt
Ex
pr
essi
on
Li
m
it
All
set
-u
ps
TRU
E
0
U
in
t8
14-
28
Pr
odu
ct
ion
Se
ttin
gs
[0
] No
actio
n
Al
l set-ups
TRU
E
-
Ui
nt8
14-
29
Se
rv
ic
e C
od
e
0 N
/A
Al
l set-ups
TRU
E
0
In
t32
1
4
-3*
Cu
rre
nt
Li
m
it
Ctrl
.
14-
30
Cu
rrent
Lim
Cont,
Pro
port
iona
l Gain
100
%
Al
l set-ups
FALSE
0
U
in
t16
14-
31
Cu
rrent
Li
m
Contr,
Integration
Ti
me
0.
02
0 s
Al
l set-ups
FALSE
-3
Ui
nt16
14-4
*
Ener
gy
Op
ti
misi
ng
14-
40
VT Le
vel
66 %
Al
l set-ups
FALSE
0
Ui
nt8
14-
41
AEO Mi
ni
mum
M
ag
neti
sati
on
40 %
Al
l se
t-up
s
TR
U
E
0
Ui
nt
8
14-
42
Mini
mum A
EO Freque
ncy
10
H
z
Al
l set-ups
TRU
E
0
Ui
nt8
14-
43
Mo
tor Cosph
i
Ex
pressio
nLimit
Al
l set-ups
TRU
E
-2
Ui
nt16
14-5
*
Env
ir
o
nme
n
t
14-
50
RFI
Fi
lter
[1] On
1 s
et
-u
p
x
FA
LS
E
-
U
in
t8
14-
52
Fa
n Cont
rol
[0] Auto
Al
l set-ups
TRU
E
-
Ui
nt8
14-
53
Fan Mo
nito
r
[1] Warn
in
g
Al
l se
t-up
s
TR
U
E
-
Ui
nt
8
14-
55
Outp
ut Fil
ter
[0
] No
Fil
ter
1 s
et
-u
p
FALSE
-
Ui
nt8
14-56
Ca
pacitan
ce
Output Fi
lter
2.
0
uF
1
set-
up
FALSE
-7
U
in
t16
14-
57
Ind
uc
tance Out
put
Fil
ter
7.
000 m
H
1 s
et
-u
p
FALSE
-6
Ui
nt16
14-7
*
Compati
b
ili
ty
14-
72
VLT Al
arm
Wo
rd
0 N
/A
Al
l set-ups
FALSE
0
Ui
nt32
14-
73
VLT
Warning
Wo
rd
0 N/
A
Al
l se
t-up
s
FALSE
0
U
in
t32
14-
74
VL
T Ext.
Statu
s W
ord
0 N
/A
Al
l set-ups
FALSE
0
Ui
nt32
4.3.13.
14-** Special Functions
VLT
®
Automation Drive FC 300
Operating Instructions High Power
4. How to Programme
MG.33.U1.02 - VLT
®
is a registered Danfoss trademark
95
4