7
VLT
®
3500 HVAC
MG.35.B1.02 – VLT is a registered Danfoss trademark
Section 1Section 1Section 1Section 1Section 1
Section 2Section 2Section 2Section 2Section 2
Section 3Section 3Section 3Section 3Section 3
Section 4Section 4Section 4Section 4Section 4
Mains supply 3 x 440/460/500 V
According to international VDE and UL/CSA
requirements
VLT type
3502
3502
3502
3502
3502 3504
3504
3504
3504
3504 3506
3506
3506
3506
3506 3508
3508
3508
3508
3508 3511
3511
3511
3511
3511 3516
3516
3516
3516
3516 3522
3522
3522
3522
3522 3532
3532
3532
3532
3532 3542
3542
3542
3542
3542 3552
3552
3552
3552
3552 3562
3562
3562
3562
3562
Output current
I
VLT,N
[A]
2.6
4.8
8.2
12.6
14.4
21.8
27.9
41.6
54.2
65.0
78.0
I
VLT, Max
(60 s) [A]
2.9
5.3
9.0
13.9
15.9
24.0
30.7
45.8
59.6
71.5
85.8
Output (at 500 V)
S
VLT,N
[kVA]
2.3
4.1
7.1
10.9
12.4
18.9
24.2
36.0
46.9
56.3
67.5
Typical shaft output
P
VLT,N
[kW]
1.1
2.2
4.0
5.5
7.5
11.0
15.0
22.0
30.0
37.0
45.0
Max. cable cross-section
[mm
2
]
2.5
2.5
2.5
2.5
2.5
16.0
16.0
16.0
35.0
35.0
50.0
Max. motor cable length
[m]
300, with screened cables: 150 m f
SW
≤
4.5 kHz
Rated motor voltage
U
M,N
[V]
440/460/500
Rated motor frequency
f
M,N
[Hz]
50/60/87/100
Max. input current
I
L,N
[A]
2.6
4.8
8.2
12.6
14.4
19.6
26.0
34.8
48.6
53.0
72.0
Max. cable cross-section
[mm
2
]
2.5
2.5
2.5
2.5
2.5
16.0
16.0
16.0
35.0
35.0
50.0
Max. pre-fuses
[A]
16
16
25
25
25
30
40
50
60
100
1
) 125
1
)
Mains contactor
4)
[Danfoss type]
CI 6
CI 6
CI 9
CI 12 CI 15 CI 6
CI 16 CI 16 CI 32 CI 32 CI 37
[AC value]
AC-3
AC-3
AC-3 AC-3
AC-3
AC-1 AC-1
AC-1
AC-1
AC-1
AC-1
Supply voltage
[V]
3 x 440/460/500 ±10% (VDE 0160)
Supply frequency
[Hz]
50/60
Power factor / cos.
ϕ
1
0.9/1.0
Switching on input
times/min.
2
Power loss at max. load
VT [W]
60
130
160
200
393
281
369
880
1133
1440
1888
Ambient temperature
[°C]
–10
→
+40 at full load
2
)
VL
VL
VL
VL
VLT type
T type
T type
T type
T type
3575
3575
3575
3575
3575
3600
3600
3600
3600
3600
3625
3625
3625
3625
3625
3650
3650
3650
3650
3650
3700
3700
3700
3700
3700
3750
3750
3750
3750
3750
3800
3800
3800
3800
3800
Output current
I
VLT,N
[A]
96
124
156
180
240
302
361
I
VLT,MAX
(60 s)[A]
106
136
172
198
264
332
397
Output (at 500 V)
S
VLT,N
[kVA]
83.1
107
135
156
208
262
313
Typical shaft output
P
VLT,N
[kW]
75
90
110
132
160
200
250
Max. cable cross-section
[mm
2
]
70
70
150
150
150
2
×
120
2
×
120
Terminal torque
[Nm]
6
6
10
10
10
6
6
Max. motor cable length
[m]
300
Rated motor voltage
U
M,N
[V]
380/400/415/440/460/500
Rated motor frequency
f
M,N
[Hz]
50/60/87/100
Max. input current
I
L,N
[A]
94.4
123.4
155.3
177.1
238.9
307.6
359.3
I
L,MAX
(60 s)[A]
106
136
172
198
264
332
397
Max. cable cross-section
[mm
2
]
120
120
2
×
120
2
×
120
2
×
120
2
×
240
2
×
240
Terminal torque
[Nm]
31.1
31.1
31.1
31.1
31.1
42
42
Pre-fuses
3
)
[A]
150
150
250
250
300
450
500
Mains contactor
4)
[Danfoss type]
CI 85
CI 85
CI 85
CI 140
CI 140
-
-
[AC value]
AC-1
AC-1
AC-1
AC-1
AC-1
-
-
Supply voltage (VDE 0160)
[V]
3
×
380/400/415/440/460/500 ±10%
Supply frequency
[Hz]
50/60
Power factor / cos.
ϕ
1
0.9/1.0
Switching on input
times/min.
1
Power loss at
Front
529
713
910
1091
1503
1812
2209
max. load [W]
Heat sink
1074
1447
1847
2216
3051
3679
4485
Ambient temperature
[°C]
-10
→
+40 at full load
2
)
1
)
Semi-conductor fuses
2
)
In the range -10 to 0°C, the equipment can start and run; however, the display values and
certain operating characteristics will not fulfil the specifications.
3
)
Bussmann rapid type JJS integrated.
4
)
If mains contactors are used, the following Danfoss types are recommended:
Max. ambient tempe40°C
■
2.1 Installation r
elated pr
oduct data