background image

General comments

Mating connectors
The SC Controller Family use Deutsch

®

 connectors. Danfoss has assembled a mating connector kit,

referred to as a bag assembly, for the 24 and 50 pin module housings. Mating connector bag assembly
ordering information is found in the product data sheet for each module.

Deutsch

®

 mating connector part information

Description

24 pin module

50 pin module

Crimp tool

HDT48-00 (solid contacts) (20 to 24 AWG)

HDT48-00 (solid contacts) (20 to 24 AWG)

DTT20-00 (stamped contacts) (16 to 20 AWG)

DTT20-00 (stamped contacts) (16 to 20 AWG)

Contacts

Solid: 0462-201-2031 (20 to 24 AWG)

Solid: 0462-201-2031 (20 to 24 AWG)

Stamped: 1062-20-0144 (16 to 20 AWG)

Stamped: 1062-20-0144 (16 to 20 AWG)

Connector plug

Gray A-Key DTM 06-12SA Black B-Key DTM
06-12SB

DRC26-50S01

Wedge

WM-12S

Not required

Strip length

3.96 to 5.54 mm [0.156 to 0.218 in]

3.96 to 5.54 mm [0.156 to 0.218 in]

Rear seal maximum insulation OD

3.05 mm [0.120 in]

2.41 mm [0.095 in]

Sealing plugs

0413-204-2005

0413-204-2005

Danfoss mating connector part information

Description

24 pin module

50 pin module

Mating connector bag assembly (20 to 24 AWG)

10100945

10100946

Mating connector bag assembly (16 to 20 AWG)

10102023

10102024

Danfoss crimp extraction tool part information

Description

Part number

Crimp tool for 20 to 24 AWG

10100745

Crimp tool for 16 to 20 AWG

10102028

Extraction tool Deutsch 114010; 12 AWG

11068808

Extraction tool Deutsch 0144-240-2005; 16 to 20, 20 to 24 AWG

10100744

PLUS+1

®

 module mating connectors may be mated 10 times.

Recommended torque for the Deutsch

®

 mating connector retaining fastener on the 50 pin connector is

2.26 N•m (20 lb•in).

Product installation

Mounting
PLUS+1

®

 modules can be mounted in one of three ways:

End (bulkhead) installation

Up to 3 units stacked on one another

Individually side mounted

In each case, care must be taken to insure that the module connector is positioned so that moisture
drains away from the connector. If the module is side or stack mounted, provide a drip loop in the

Technical Information

PLUS+1 SC0XX-1XX Controller Family

Product installation and start-up

 

22 | 

©

 Danfoss | June 2016

L1415500 | BC00000235en-US0201

Summary of Contents for PLUS+1 SC0XX-1 Series

Page 1: ...Technical Information PLUS 1 SC Controllers SC0XX 1XX Controller Family powersolutions danfoss com...

Page 2: ...log Resistance 4 20 mA Current DIN AIN ResIN CrntIN Specifications 0201 March 2015 Various text update and added tables for control of outputs BA December 2014 First edition AA Technical Information P...

Page 3: ...cations CAN Controller Area Network 16 CAN system design 16 Specifications for terminating resistor 16 Notes on CAN Bus installation 16 Expansion module CAN Bus loading 16 Internal processor to proces...

Page 4: ...riable settings API specifications are the definitive source of information regarding pin characteristics PLUS 1 GUIDE User Manual This user operation manual OM details information regarding the PLUS...

Page 5: ...e OS that is embedded in their respective SC0XX 1XX HWD files The SC0XX 0XX Controller Family is designed for meeting the needs of SIL 2 applications where the OEM certifies at the machine level The S...

Page 6: ...hat are used for development testing configuration management quality control etc comply with the 250 requirements of the IEC 61508 international standard Use of certified devices makes it much easier...

Page 7: ...nput or output types are user configurable using PLUS 1 GUIDE software Refer to product data sheets for the input output I O content of individual modules Technical Information PLUS 1 SC0XX 1XX Contro...

Page 8: ...atching reading saturates to the high limit Response to input open Pin configuration dependent No pull up no pull down floating Pull up to 5 Vdc 5 Vdc Pull down 0 Vdc Pull up pull down 2 5 Vdc Voltage...

Page 9: ...ll down pull up is standard with pull up or pull down programmable failure modes are detectable Maximum frequency The controller may re boot under some high frequency load conditions above 10 kHz Spec...

Page 10: ...uired for frequency input to read low Rising voltage threshold low range Vdc 0 11 0 30 Voltage required for frequency input to read high Falling voltage threshold low range Vdc 0 04 0 22 Voltage requi...

Page 11: ...case error high range Vdc 1 16 Over the full temperature range 40 C to 85 C 40 F to 185 F Maximum discernable voltage middle range Vdc 5 13 5 38 Minimum discernable voltage middle range mV 0 20 Precis...

Page 12: ...the module s output pin To protect against unintended movement secure the machine C Caution Warranty will be voided if module is damaged by significant current driven back through an output pin Digit...

Page 13: ...to the off state 3 The secondary application can then re enable the output BIT 8 Hardware supply power out of range 1 The primary application must command ALL outputs to the off state 2 The supply vo...

Page 14: ...A 0 25 Repeatability of full range of full scale 0 5 Absolute accuracy of full range of full scale 0 3 Output settling time ms 100 Depends on load characteristics PWM frequency Hz 33 4000 and 20 000 D...

Page 15: ...put BIT 8 Hardware supply power out of range 1 The primary application must command ALL outputs to the off state 2 The supply voltage must return to its valid range 3 The kernel then clears status bit...

Page 16: ...of the CAN_H and CAN_L conductors This termination resistance should be connected between the CAN_H and CAN_L conductors Specifications Description Units Minimum Maximum Nominal Comment Resistance 11...

Page 17: ...nostics The hardware and low level software provide a basic framework for communication on each channel however the specific data structure is not predefined because the data to be transferred is appl...

Page 18: ...ure gives OEM designers the ability to implement automotive like features in their machine control system design If the lower power mode feature is not implemented this controller has the same operati...

Page 19: ...aximum Comment Output short circuit voltage Vdc 36 Sensor output voltage Vdc 3 12 Output current mA 0 500 The maximum power must be limited to 2 5 Watts for Vout greater than 5 Vdc Output Load Capacit...

Page 20: ...85 185 Storage temperature C F 40 40 85 185 Allowable module supply voltage Vdc 7 36 Module sensor supply voltage Vdc 3 12 Sensor voltage drops below the minimum value if module supply voltage 7 Vdc...

Page 21: ...ibility for earth moving machinery Electrostatic discharge EN 60 1 000 4 2 Auto electrical transients ISO 7637 2 ISO 7637 3 Short circuit protection Danfoss test Inputs and outputs survive continuous...

Page 22: ...05 0413 204 2005 Danfoss mating connector part information Description 24 pin module 50 pin module Mating connector bag assembly 20 to 24 AWG 10100945 10100946 Mating connector bag assembly 16 to 20 A...

Page 23: ...on modules be connected to a common ground A dedicated ground wire of appropriate size connected to the machine battery is recommended Hot plugging Machine power should be off when connecting PLUS 1 m...

Page 24: ...US 1 USB CAN Gateway Communication software uploads and downloads and service and diagnostic tool interaction between PLUS 1 modules and a personal computer PC is accomplished using the vehicle s PLUS...

Page 25: ...Technical Information PLUS 1 SC0XX 1XX Controller Family Danfoss June 2016 L1415500 BC00000235en US0201 25...

Page 26: ...Technical Information PLUS 1 SC0XX 1XX Controller Family 26 Danfoss June 2016 L1415500 BC00000235en US0201...

Page 27: ...Technical Information PLUS 1 SC0XX 1XX Controller Family Danfoss June 2016 L1415500 BC00000235en US0201 27...

Page 28: ...DK 6430 Nordborg Denmark Phone 45 7488 2222 Danfoss Power Solutions US Company 2800 East 13th Street Ames IA 50010 USA Phone 1 515 239 6000 Danfoss Power Solutions Trading Shanghai Co Ltd Building 22...

Reviews: