Guide line | Trouble shooting guide for PAH, PAHT, PAHT C , PAHT G, PAHT 674 and PAH F pumps
66
180R9316 | AQ176586503002en-000501 | IOM PAHT C 2-6.3 pumps | 01.2022
Picture 1
If the port plate has scratches, level differences or both between the arrows,
the port plate must be replaced .
Even small scratches or wear will cause loss of flow .
To check: See item 6 .1, picture 3
6.2 Port plate
6.3 Swash plate
Picture 1
If the swash plate is polished 360°, it is an indication of insufficient filtration .
The surface of the swash plate must be plane and even at same level all over .
To check this, please see item 6 .1, picture 3 .
If the surface has any marks/scratches, it is worn/damaged and a new one
is required .
Please contact Danfoss High Pressure Pumps sales office for further infor-
mation .
Scratc
hes
Level d
ifferenc
es be
tween
dull an
d shinin
g PEE
K
Summary of Contents for PAHT C
Page 30: ...Danfoss DCS im 2017 06 521B1374 A 234386502982en000401 PAHT C pumps UK 06 2017 30...
Page 46: ...46 180R9316 AQ176586503002en 000501 IOM PAHT C 2 6 3 pumps 01 2022...
Page 75: ...180R9316 AQ176586503002en 000501 IOM PAHT C 2 6 3 pumps 75 Danfoss DCS im 2022 01...
Page 76: ...Danfoss DCS im 2022 01 76 180R9316 AQ176586503002en 000501 IOM PAHT C 2 6 3 pumps...