Choice of material
.
Rubber
.
Plastic
.
Stainless steel
1.
.
Iron
.
Copper
.
Brass
.
Aluminium
Always use system components made
of corrosion proof materials
Non-corrosion proof materials
may cause damage
Choice of filter
2.
Install a 10 micron absolute filter with
pressure switch
< 10
m
m
abs.
> 10
m
m
Return filter with bypass valve and
poorer filterability than 10
m
will
damage the system
Filter location
3.
Locate the return filter in the return line
immediately before the tank
Placing the return filter upstream of the
final load may damage the pump
Pump location
4.
Pump always to be placed below water
surface level
Pump location above water surface
level will cause damage
Water supply
7.
System to be filled via filter
Filling system with unfiltered
water causes damage
6.
Pressure Relief valve
Pressure relief valve to be mounted
vertically or with vertical outlet and
connected to return hose or tank
Coupling the pressure relief valve outlet
directly to the pump inlet may damage
the pump
Suction conditions
5.
System to be dimensioned to provide
a suction pressure of the pump inlet of
max. 0.1 bar vacuum
Poor suction conditions will cause
malfunction and damage the pump
Design
70 | © Danfoss | DCS (im) | 2022 .01
180R9316 | AQ176586503002en-000501 | IOM PAHT C 2-6.3 pumps
Summary of Contents for PAHT C
Page 30: ...Danfoss DCS im 2017 06 521B1374 A 234386502982en000401 PAHT C pumps UK 06 2017 30...
Page 46: ...46 180R9316 AQ176586503002en 000501 IOM PAHT C 2 6 3 pumps 01 2022...
Page 75: ...180R9316 AQ176586503002en 000501 IOM PAHT C 2 6 3 pumps 75 Danfoss DCS im 2022 01...
Page 76: ...Danfoss DCS im 2022 01 76 180R9316 AQ176586503002en 000501 IOM PAHT C 2 6 3 pumps...