Data sheet | PAHT C 2-6.3 pumps
22
180R9316 | AQ176586503002en-000501 | IOM PAHT C 2-6.3 pumps | 01.2022
4.
Technical data
4.1 PAHT C 2-6.3
Pump size
2
3.2
4
6.3
Code number PAHT C
180B1030
180B1031
180B1032
180B1033
Code number ATEX PAHT C
180B1130
180B1131
180B1132
180B1133
Housing material
AISI 304
AISI 304
AISI 304
AISI 304
Sealing material
FFKM
FFKM
FFKM
FFKM
Geometric
displacement
cm³/rev
2
3 .2
4
6 .3
in³/rev
0 .12
0 .20
0 .24
0 .38
Pressure
Min. outlet
pressure
barg
30
30
30
30
psig
435
435
435
435
Max. outlet
pressure
barg
100
100
100
100
psig
1450
1450
1450
1450
Inlet pressure,
continuous
barg
0-4
0-4
0-4
0-4
psig
0-58
0-58
0-58
0-58
Max. inlet
1)
pressure, peak
barg
4
4
4
4
psig
58
58
58
58
Speed
Min. speed
rpm
1000
1000
1000
1000
Min. speed,
continuous
rpm
1000
1000
1000
1000
Max. speed
rpm
3000
3000
3000
3000
Typical flow - Flow curves available in section 5
2)
1000 rpm at
max. pressure
l/min
0 .7
2 .0
3 .0
5 .5
1500 rpm at
max. pressure
l/min
1 .7
3 .6
5 .0
8 .6
1200 rpm at
max. pressure
gpm
0 .3
0 .7
1 .0
1 .8
1800 rpm at
max. pressure
gpm
0 .6
1 .2
1 .6
2 .7
Typical motor size
1500 rpm at
max. pressure
kW
50 Hz
0 .75
1 .1
1 .5
2 .2
1800 rpm at
max. pressure
hp
60 Hz
1 .0
1 .5
2 .0
3 .0
Torque at max.
outlet pressure
Nm
4 .4
6 .7
8 .1
12 .4
lbf-ft
3 .2
4 .9
6 .0
9 .2
Media
temperature
°C
2-50
2-50
2-50
2-50
°F
37-122
37-122
37-122
37-122
Ambient
temperature
°C
0-50
0-50
0-50
0-50
°F
32-122
32-122
32-122
32-122
Sound pressure
level
3)
dB(A)
76
76
76
76
Weight
kg
4 .4
4 .4
4 .4
4 .4
lbs
9 .7
9 .7
9 .7
9 .7
1)
1% per minute peak, 10% per minute during start up .
2)
Values measured in water, might differ in other media .
3)
Measurements according to EN ISO 3744: 2010 / dB(A) [L
PA, 1m
] values are calculated .
Measured at max pressure and rpm for a motor pump unit .
Summary of Contents for PAHT C
Page 30: ...Danfoss DCS im 2017 06 521B1374 A 234386502982en000401 PAHT C pumps UK 06 2017 30...
Page 46: ...46 180R9316 AQ176586503002en 000501 IOM PAHT C 2 6 3 pumps 01 2022...
Page 75: ...180R9316 AQ176586503002en 000501 IOM PAHT C 2 6 3 pumps 75 Danfoss DCS im 2022 01...
Page 76: ...Danfoss DCS im 2022 01 76 180R9316 AQ176586503002en 000501 IOM PAHT C 2 6 3 pumps...