Instruction
Pump instruction PAHT C 2-6.3
36
180R9316 | AQ176586503002en-000501 | IOM PAHT C 2-6.3 pumps | 01.2022
3.
Building up the
pump unit
We recommend a separation (“wall”) to separate
the inlet from the outlet end of the tank .
Monitoring
It is recommended to continuously monitor the
following conditions:
•
Water level in the tank
•
Filter contamination
•
Pressure (inlet- and outlet side of the
pump)
3.1 Mounting
If alternative mounting is desired, please contact
the Danfoss Sales Organization .
Choose proper tolerances to ensure an easy
mounting of the elastic coupling without use of
tools .
Please take care to observe the recommended
length tolerances of the chosen coupling, as an
axial force on the pump shaft must be avoided .
3.2 Direction of rotation
Is indicated by means of an arrow at the label of
the pump .
3.3 Orientation
The pump can be mounted/orientated in any
direction .
Between 3–5 mm.
[0, 1–0, 2 Inch.]
A: Elastic coupling
B: Bell housing
C: Motor shaft
Summary of Contents for PAHT C