background image

  

2) In 90° bends

2) In 90° Winkeln

1)  In smooth pipes and hoses

1)  In geraden Rohren und Schläuchen

2.4 General comments on

Filtration

A good fi ltration is vital to ensure a long and trouble free life of the 
pump. 

When selecting a fi lter or strainer, please note that fi lter materials should 
be compatible with water, i.e. should neither corrode or dissolve. Also be 
aware of the electrochemical series of the applied materials.

 Main 

fi lter must have a fi neness of 10 μm abs.ß

10

 >5000.

 

The pressure loss across the fi lter should be monitored.

 

Please contact the Danfoss Sales Organization for further fi lter 

 details.

Water tank

Must be made of corrosion-proof material such as stainless steel or 
plastic and must be sealed to prevent entrance of impurities from 
the environment.

Automatic pressure equalization between tank and surroundings must 
be ensured.

Inlet from the water supply (the return line) and inlet to the pump should 
be placed in opposite ends of the tank to calm and deaerate the water, 
and to ensure optimum opportunity for particles to settle.

2.4 Generelle Bemerkungen über

Filtrierung

Eine gute Filtrierung ist für eine lange Lebensdauer der Pumpe uner-
läßlich.

Wenn Sie Filter oder Sieb wählen, beachten Sie bitte, daß das Filtermate-
rial Wasserverträglich sein muß, d.h. es darf weder korrodieren noch was-
serlöslich sein. Beachte auch die elektrochemischen Ausführungen der 
verwendeten Materialien.  

 Das 

Hauptfi lter muß eine Feinheit von 10 μm Abs. ß

10

 >5000  

haben.

 

Der Druckverlust über das Filter sollte überwacht werden.

 

Nach weiteren Einzelheiten über Filtrierung erkundigen Sie sich 

 

bitte bei Ihrer Danfoss Verkaufsorganisation.

Wassertank

Muß aus nichtrostendem Material wie rostfreiem Stahl oder Plastik sein. 
Um das Eindringen von Schmutzpartikeln aus den Umgebungen zu ver-
hindern, muß der Behälter verschlossen sein.

Der Druckausgleich zwischen Tank und Umgebung muß gewähr-
leistet sein.

Wasserversorgungseinlaß und die Saugleitung der Pumpe sollten mög-
lichst weit auseinander angebracht werden um das Wasser in einem Zu-
stand zu stillen und dadurch die best möglichen Voraussetzungen für 
das Absetzen von Partikeln zu schaff en.

General guidelines for calculation of pressure losses

Generelle Richtlinien für die Berechnung von Druckverlusten

Summary of Contents for PAHF 20

Page 1: ...Dimension the inlet line with a minimum pressure loss large flow area minimum length of pipe minimum number of bends connections fittings with small pressure losses 1 Bezeichnung 2 Systemaufbau M gli...

Page 2: ...sbereich minimale Rohrl nge mini male Anzahl von Winkelverschraubungen und Verschraubungen mit kleinem Druckverlust In order to avoid the risk of cavitation the inlet pressure at the pump must be min...

Page 3: ...ity for particles to settle 2 4 Generelle Bemerkungen ber Filtrierung Eine gute Filtrierung ist f r eine lange Lebensdauer der Pumpe uner l lich Wenn Sie Filter oder Sieb w hlen beachten Sie bitte da...

Page 4: ...Tank Verschmutzung des Filters Druck Ein und Ausla seite der Pumpe Temperatur Einla seite der Pumpe 3 Aufbau der Pumpeneinheit 3 1 Montage If alternative mounting is desired please contact the Danfoss...

Page 5: ...ressure side The valve should be placed as close to the pump as possible The opening characteristics of the valve must not result in peak pressures higher than 200 bar 3000 psi 3 3 Einbaulage Die Pump...

Page 6: ...flushed prior to initial start up of the pump to ensure that impurities are removed Warning Make sure that the direction of rotation of the electric motor corresponds to the direction of rotation of t...

Page 7: ...5 6 3 Open ended systems with direct water supply 5 Betrieb 5 1 Wasserqualit t Wasser von Trinkwasserqualit t nach EU Direktive 98 83 EC und ohne abresiven Sedimenten VE Wasser enth rtetem Wasser und...

Page 8: ...sserhydrauliksysteme Wasser rezirkuliert 1 Die Verbindung zwischen Pumpenstation und System trennen 2 Das Wasser aus dem Tank ablassen Den Tank mit Frost schutzmittel bis reichlich ber der Ansaugleitu...