If
[1] Serial communication
is selected, commands are
activated only when given via serial communication.
Terminal
Bit 02/03/04
Function
0
0
Stop/Anti-clockwise
0
1
Start/Clockwise
1
0
Stop/Anti-clockwise
1
1
Start/Clockwise
Table 10.9 [1] Serial communication
If
[2] Logic AND
is selected, both signals must be activated
to perform the function.
Terminal
Bit 02/03/04
Function
0
0
Stop/Anti-clockwise
0
1
Stop/Anti-clockwise
1
0
Stop/Anti-clockwise
1
1
Start/Clockwise
Table 10.10 [2] Logic AND
If
[3] Logic OR
is selected, activation of one signal activates
the function.
Terminal
Bit 02/03/04
Function
0
0
Stop/Anti-clockwise
0
1
Start/Clockwise
1
0
Start/Clockwise
1
1
Start/Clockwise
Table 10.11 [3] Logic OR
The effect of control mode upon the function of
8-55 Set-
up Select
and
8-56 Preset Reference Select
:
If
[0] Digital input
is selected, the terminals control the set-
up and preset reference functions.
Terminal
Bit 00/01,
13/14
Function
Msb
Lsb
Msb
Lsb
Preset ref., Set-up no.
0
0
0
0
1
0
0
0
1
1
0
0
1
0
1
0
0
1
1
1
0
1
0
0
2
0
1
0
1
2
0
1
1
0
2
0
1
1
1
2
1
0
0
0
3
1
0
0
1
3
1
0
1
0
3
1
0
1
1
3
1
1
0
0
4
1
1
0
1
4
1
1
1
0
4
1
1
1
1
4
Table 10.12 [0] Digital input
If
[1] Serial communication
is selected, commands are
activated only when given via serial communication.
Terminal
Bit 00/01, 13/14 Function
Msb
Lsb
Msb
Lsb
Preset ref., Set-up no.
0
0
0
0
1
0
0
0
1
2
0
0
1
0
3
0
0
1
1
4
0
1
0
0
1
0
1
0
1
2
0
1
1
0
3
0
1
1
1
4
1
0
0
0
1
1
0
0
1
2
1
0
1
0
3
1
0
1
1
4
1
1
0
0
1
1
1
0
1
2
1
1
1
0
3
1
1
1
1
4
Table 10.13 [1] Serial communication
Troubleshooting
MCA 124 EtherCAT Operating Instruction
MG92A302 - VLT
®
is a registered Danfoss trademark
47