Service guide
|
Disassembling and Assembling, iSave 50-70
© Danfoss | DCS (im) | 2016.10
8 | 180R9387 | 521B1430 | DKCFN.PI.013.1H.02
23.The rotor elements can only be pushed
in until the surface is slightly above the
rotor surface. There is
not
any special
placement of the grooves in the rotor
elements.
24. The O-ring will try to slip out in the 2 cut
out holes. Carefully press it in with a
small screwdriver.
25. Remove the 8 vanes from the stator
housing.
26. Remove the green spider from the internal
coupling.
27. Unscrew the 4 coupling screws using
the 6 mm allen socket.
28. Remove the coupling from the cylinder
shaft. If sticking, screw in 2 x M5 bolts
(not in tool kit) which will allow a better