Service guide
|
Disassembling and Assembling, iSave 50-70
© Danfoss | DCS (im) | 2016.10
180R9387 | 521B1430 | DKCFN.PI.013.1H.02 | 23
20. Mount the spider and the bell housing
over the shaft seal cover outside diameter.
18. Lubricate the shaft.
Mount the key in the shaft end and mount
the coupling. Adjust the coupling and
flange distance to the same as measured
before the disassembling.
19. Tighten the screw inside the coupling to
the torque according to exploded view.
21. Lubricate the 4 screws and mount the
washers and screws inside the bell
housing. Tighten the screws to the
torque according to exploded view.
17. Lubricate the screws. Mount a new O-ring
on the shaft cover and mount it on the
motor flange. Tighten the screws to the
torque according to exploded view.
22. Carefully lift the electrical motor from the
support.