Service guide
|
Disassembling and Assembling, iSave 50-70
© Danfoss | DCS (im) | 2016.10
180R9387 | 521B1430 | DKCFN.PI.013.1H.02 | 19
4. Lubricate the stud bolt threads. Mount the
6 Stud bolt washer and nuts below the
exchange connection flange.
6. Mount the 2 pins in the cylinder shaft end.
5. Cross tighten to the torque according to
exploded view.
7. Lubricate the coupling screw.
Mount one internal coupling part and
mount 4 coupling screws.
8. Cross tighten to the torque according to
exploded view.
3. Check that the small pin is in correct
position.