Service guide
|
Disassembling and Assembling, iSave 50-70
© Danfoss | DCS (im) | 2016.10
10 | 180R9387 | 521B1430 | DKCFN.PI.013.1H.02
35. Unscrew and remove the lifting eyes
and lifting strap and turn the stator
housing up so that the port plate is
upwards to avoid damage.
36. Remove the port plate from the 2 clips
using a screwdriver.
37. Visually check the port plate for wear/
scratches and using a straight edge
ruler across the sealing surfaces and
replace if needed.
38. Remove the 2 clips, 2 pins and the O-ring.
39. Remove the small pin for fixing the
exchanger housing in the intermediate
flange.