11. Put a small amount of lubricant in the
hole. Lubricate the rotor stop and hole
with clean filtered water and carefully by
hand press in the rotor stop.
12. Lubricate the O-rings, side plate and
flange with clean filtered water.
Mount the first O-ring in the cut out in the
flange.
13. Mount the second new O-ring in the
bottom on the flange.
14. It is important that the inside groove in
the side plates are pointing upwards
16 Remove the 2 pins in the stator housing.
15.Carefully by hand only press down the side
plate.
Always change rotor stop and side
plate at the same time as changing the