7.2 Commonly Used Parameters -
Explanations
0-01 Language
Option:
Function:
Defines the language to be used in the
display.
The frequency converter can be delivered
with 2 different language packages.
English and German are included in both
packages. English cannot be erased or
manipulated.
[0]
*
English
Part of Language packages 1 - 2
[1]
Deutsch
Part of Language packages 1 - 2
[2]
Francais
Part of Language package 1
[3]
Dansk
Part of Language package 1
[4]
Spanish
Part of Language package 1
[5]
Italiano
Part of Language package 1
[6]
Svenska
Part of Language package 1
[7]
Nederlands
Part of Language package 1
[10]
Chinese
Language package 2
[20]
Suomi
Part of Language package 1
[22]
English US
Part of Language package 1
[27]
Greek
Part of Language package 1
[28]
Bras.port
Part of Language package 1
[36]
Slovenian
Part of Language package 1
[39]
Korean
Part of Language package 2
[40]
Japanese
Part of Language package 2
[41]
Turkish
Part of Language package 1
[42]
Trad.Chinese
Part of Language package 2
[43]
Bulgarian
Part of Language package 1
[44]
Srpski
Part of Language package 1
[45]
Romanian
Part of Language package 1
[46]
Magyar
Part of Language package 1
[47]
Czech
Part of Language package 1
[48]
Polski
Part of Language package 1
[49]
Russian
Part of Language package 1
[50]
Thai
Part of Language package 2
[51]
Bahasa Indonesia Part of Language package 2
[52]
Hrvatski
0-20 Display Line 1.1 Small
Option:
Function:
Select a variable for display in line 1, left
position.
[0]
*
None
No display value selected
[37]
Display Text 1
Enables an individual text string to be
written, for display in the LCP or to be
read via serial communication.
[38]
Display Text 2
Enables an individual text string to be
written, for display in the LCP or to be
read via serial communication.
[39]
Display Text 3
Enables an individual text string to be
written, for display in the LCP or to be
read via serial communication.
[89]
Date and Time
Readout
Displays the current date and time.
[953]
Profibus
Warning Word
Displays Profibus communication
warnings.
[1005]
Readout
Transmit Error
Counter
View the number of CAN control
transmission errors since the last power-
up.
[1006]
Readout
Receive Error
Counter
View the number of CAN control receipt
errors since the last power-up.
[1007]
Readout Bus
Off Counter
View the number of Bus Off events since
the last power-up.
[1013]
Warning
Parameter
View a DeviceNet-specific warning word.
One separate bit is assigned to every
warning.
[1115]
LON Warning
Word
Shows the LON-specific warnings.
[1117]
XIF Revision
Shows the version of the external
interface file of the Neuron C chip on the
LON option.
[1118]
LonWorks
Revision
Shows the software version of the
application program of the Neuron C
chip on the LON option.
[1501]
Running Hours
View the number of running hours of the
motor.
[1502]
kWh Counter
View the mains power consumption in
kWh.
[1600]
Control Word
View the Control Word sent from the
frequency converter via the serial
communication port in hex code.
[1601]
Reference
[Unit]
Total reference (sum of digital/analog/
preset/bus/freeze ref./catch up and
slow-down) in selected unit.
[1602]
*
Reference [%]
Total reference (sum of digital/analog/
preset/bus/freeze ref./catch up and
slow-down) in percent.
How to Programme the Frequ...
VLT
®
HVAC Drive Operating Instructions
MG.11.AD.02 - VLT
®
is a registered Danfoss trademark
65
7
7