8
VMBMA602
2.2
DHP-H Opti Pro
Dimensions and connections
The brine pipes can be connected on either the left or right-hand
sides of the heat pump.
DHP-H, DHP-H Opti Pro and connections.
Figure 6:
Position Name
1
Brine in, 28 Cu
2
Brine out, 28 Cu
3
Heating system supply line, 22 Cu: 4-10 kW, 28 Cu: 12-16 kW
4
Heating system return line, 22 Cu: 4-10 kW, 28 Cu: 12-16 kW
5
Expansion line, 22 Cu
6
Hot water line, 22 Brass
7
Cold water line, 22 Brass
8
Lead-in for supply, sensor and communication cables
9
Safety valve for temperature and pressure (mounted only on cer-
tain models, see chapter 6)
11
0
1845 (±10)
455
596
528
300
440
40±10
1
2
610
80
4
7
8
6
5
9
3