55
VMBMA602
Sub menu INFORMATION -> DEFROST (
DHP-A, -AL
)
The menu applies to DHP-A, -AL with defroster card and only appears if OUTDOOR AIR in the SERVICE -> INSTALLATION -> SYSTEM -> HEAT
SOURCE menu is selected. Used to obtain information about outdoor unit defrosting and to make certain settings.
Menu selection
Meaning
Factory setting
DEFROSTS
Total number of defrosts carried out.
-
BETW. 2 DEFR
The operating time of the compressor in minutes between the 2 last defrosts.
-
TIME SINCE DEFROST
The operating time of the compressor in minutes since last defrost.
-
FAN H OFF AT
Fan high speed is deactivated at this temperature and low speed is activated.
12°C
(interval: 10°C / 20°C)
DEFROST CURVE
Here, the angle of the defrost curve can be changed using the right-hand arrow
and by either pr or – (Change the start temperature for defrost).
-10°C
(interval: -13°C / -7°C)
MANUEL DEFR
By using the right-hand arrow + or -, defrost can be started manually (shunts
+20°C for 10 minutes).
0 (interval: 0 / 1)