14
VMBMA602
2.5
DHP-A, DHP-A Opti
Dimensions and connections
The brine pipes can be connected on either the left or right-hand
sides of the heat pump.
DHP-A, DHP-A Opti, Dimensions and connections.
Figure 12:
Position Name
1
Brine in, 28 Cu
2
Brine out, 28 Cu
3
Lead-in for incoming power supply, sensors and communication
cable
4
Heating system supply line, 22 Cu: 6-10 kW, 28 Cu: 12 kW
5
Heating system return line, 22 Cu: 6-10 kW, 28 Cu: 12 kW
6
Expansion pipe, 22 Cu
7
Hot water pipe, 22 Brass
8
Cold water pipe, 22 Brass
9
Expansion outlet brine circuit, DN25 int.
10
Safety valve for temperature and pressure (mounted only on cer-
tain models, see chapter 6)
Outdoor unit, Dimensions and connections.
Figure 13:
Position Name
1
Brine in (from HP Brine out) 28 Cu
2
Brine out (to HP Brine in) 28 Cu
Outdoor unit components and connections
Figure 14:
Position Name
1
Outdoor unit
2
Cover
3
Front cover
4
Stand
5
Cover
6
Connection, brine in
7
Connection, brine out
8
Connection, drain drip tray
Check that the delivery of the outdoor unit contains the following:
• Outdoor unit
• Disassembled stand
• Necessary screws, nuts and washers.
• Defroster sensor
1845 (±10)
455
596
528
258
250
300
40±10
1
2
1
1
2
2
1175
630
405
441
342
300
1205
910
6
7
8
1
2
3
4
5
610
80
5
7 8
9
6
10
3
4