background image

OPERATING INSTRUCTIONS

KEY PAD FEATURES

LED DISPLAY: 

Displays the following information

independently;Set Temperature, Ambient
RoomTemperature and Auto Timer On/Off settings.

POWER:

Turns unit On/Off.

MODE:

Allows you to scroll through and select

the desired operating mode; Cool , Dry , Fan Only
and *Auto .The selected mode will be denoted by the
adjacent indicator light.*‘Auto’is a pre-set factory
program that automatically defines the mode (Cool or
Dry) and fan speed based on the set temperature

FAN SPEED:

Select from four different fan 

settings;Low , Medium , High and Auto during Cool
and Fan Only mode. Please note: During ‘Dry’ mode
the fan speed is automatically defined .

ENERGY SAVER:

Automatically cycles the fan

on and off while the compressor is not in use.

TEMP / TIMER CONTROL:

Used to

increase or decrease the Temperature setting in 1°C /
°F increments, and Auto-Timer On/Off 
settings in 30min./1hr. increments. 

Note:

This 

appliance allows you select the temperature scale to
be displayed in either “Celsius” or Fahrenheit”
according to your preference.To change the 
temperature scale displayed on the electronic display,
press both the “Temp/Timer”adjust arrows 
simultaneously to alternate between
“Celsius”&“Fahrenheit”.

CHECK FILTER: 

The adjacent indicator light

will illuminate as a reminder to clean the air 
conditioner filter (see page 9)  Once the filter has
been cleaned and replaced, depress the Check Filter
button in order to resume operation.

SLEEP MODE:

When activated, the current set

temperature is gradually increased over a one (1) hour
period then maintained for seven (7) hours. Once the
program is complete, the air conditioner will resume
to its previous set temperature (before sleep mode was 
activated). This feature is mean to be used during the
night time hours to prevent the room from getting too
cold (while you sleep) and results in less compressor
running time and reduced energy consumption. Sleep
mode may be cancelled by depressing the Sleep Mode 
button while the program is running.

AUTO-TIMER:

Used to initiate the Auto On/

Auto Off timer.

While the Air Conditioner is off (Auto-On):
1)

Press the Auto-Timer button once and the adjacent

Auto-On indicator light will illuminate.

2)

Use the Temp/Timer control cursors to select a

delayed On time of up to 24 hours. 

3)

Select the appropriate mode under which you want

the unit to operate (Auto-Cool-Dry-Fan Only)

4)

Select the fan speed setting.

5)

The time you selected will appear in the LED 

display. 

While the Air Conditioner is on (Auto-Off):
1)

Press the Auto-Timer button twice and the adjacent

Auto-Off indicator light will illuminate.

2)

Use the Temp/Timer control cursors to select a

delayed Off time of up to 24 hours.

3)

The time you selected will appear in the LED

display. The Auto On and Auto Off timer can 
operate during the same program by defining the
Auto-Off parameters immediately after the Auto On
parameters.  The Auto-Timer may be cancelled at
any time by turning the unit On/Off.

Temp/Timer

Control

Check

Filter

Mode

Selector

Energy

Saver

LED

DISPLAY

Auto

Timer

Sleep

Mode

Fan 

Speed

Power

Button

6

Summary of Contents for DAC10010E

Page 1: ...doit tre inclus avec l appareil CAUTION Read and follow all safety rules and operating instructions before first use of this product MISE EN GARDE Veuillez lire attentivement les consignes de s curit...

Page 2: ...rough the wall installation For easy reference may we suggest you attach a copy of your sales slip receipt to this page along with the following information located on the manufacturers nameplate on t...

Page 3: ...wall outlet must match the 3 prong plug on the service cord supplied with the unit DO NOT use plug adapters See Table 2 for receptacle and fuse information If it is necessary to use an extension cord...

Page 4: ...talling or servicing 3 4 19 1mm screws 9 Factory installed on some models Safety Lock 1 Adhesive Foam Seal 1 Sash bracket 2 L Shaped mounting bracket 1 INSTALLATION HARDWARE Your Room Air Conditioner...

Page 5: ...tain the proper electrical outlet is within reach of the installation Use only a single outlet circuit rated at 15 amps All wiring should be in accordance with local and national electrical codes F DO...

Page 6: ...each side and secure the top of the frames to the window sash using one 3 4 screw on each side and one in the L shaped mounting bracket Fig 5 Secure the shutter clamp on each side of the lower shutter...

Page 7: ...ration SLEEP MODE When activated the current set temperature is gradually increased over a one 1 hour period then maintained for seven 7 hours Once the program is complete the air conditioner will res...

Page 8: ...nds in order to set the clock Press the increase or decrease arrow to adjust the clock in 1 minute intervals holding down the increase or decrease arrow will adjust the time in 10 minute intervals 10...

Page 9: ...Dry thoroughly before re installing CLEANING AIR FILTER 1 Use a vacuum cleaner with soft brush attachment 2 Wash the filter in lukewarm water below 40 C 104 F To get best results wash with soapy water...

Page 10: ...inappropriate for application Blocked air flow Power interruption settings changed too quickly or compressor overload tripped Clean replace air filter Check with dealer to determine proper unit capac...

Page 11: ...de l appareil Inscrivez les renseignements suivants fournis sur la plaque signal tique du fabricant sur le c t droit de l appareil au dessus du cordon d alimentation Vous aurez besoin de ces renseigne...

Page 12: ...ien qualifi 5 La prise murale doit correspondre la fiche 3 broches sur le cordon de service fourni avec l appareil N utilisez PAS de fiches d adaptation Voir Tableau 2 pour les renseignements sur les...

Page 13: ...droit ce c t est plus lourd et plus difficile manipuler Un soutien inappropri du c t des commandes de l appareil peut causer des blessures et endommager l appareil et d autres biens mobiliers C est po...

Page 14: ...pi ce puissent bloquer le flux d air E Assurez vous que la prise lectrique appropri e se trouve la port e de l installation N utilisez qu un circuit prise unique calcul 15 amp res Tout le c blage doi...

Page 15: ...s volets compl tement de chaque c t et fixez le haut des structures au cadre de la fen tre en utilisant une vis de 3 4 po et une rondelle de s curit sur chaque c t Fig 5 Coupez la bande mousse adh sif...

Page 16: ...meil Le mode de sommeil augmentera votre temp rature de climatisation pr r gl e graduellement pendant une p riode de un 1 heures la nouvelle temp rature est maintenue pendant sept 7 heures Une fois qu...

Page 17: ...et la t l commande pourrait causer une interf rence au signal ce qui limiterait la capacit de programmation de l unit principale Affichage lectronique 17 7 Annuler le programme Minutrie en Marche et...

Page 18: ...lisez un aspirateur de poussi re muni d une brosse douce 2 Lavez le filtre dans de l eau ti de de moins de 40 C 104 F Pour obtenir de meilleurs r sultants lavez avec une eau savonneuse ou un agent neu...

Page 19: ...ement ou compresseur d clench par surcharge Nettoyez ou remplacez le filre air Verifiez avec le concessionnaire si la capacit de l appareil est appropri e son application Enlevez l objet qui obstrue l...

Page 20: ...you call the TOLL FREE NUMBER When requesting service or ordering parts always provide the following information Product Type Model Number Part Number Part Description CLIMATISEUR Le num ro de mod le...