READ ALL SAFETY INFORMATION BEFORE USING

1)

All wiring must comply with local and national electrical

codes and must be installed by a qualified electrician. If you
have any questions regarding the following instructions, 
contact a qualified electrician. 

2)

Check available power supply and resolve any wiring 

problems BEFORE installing and operating this unit.

3)

This 115V air conditioner uses 10 or less nameplate amps

and may be used in any properly wired, general purpose
household receptacle. See Table 1 for specifications for 
individual branch circuit.

4)

For your safety and protection, this unit is grounded

through the power cord plug when plugged into a matching
wall outlet. If you are not sure whether your wall outlet is
properly grounded, please consult a qualified electrician. 

5)

The wall outlet must match the 3-prong plug on the service

cord supplied with the unit. DO NOT use plug adapters. See
Table 2 for receptacle and fuse information. If it is necessary
to use an extension cord to connect your air conditioner, 

use

an approved “air conditioner” extension cord only 

(available at most local hardware stores). 

6)

The rating plate on the unit contains electrical and other

technical data. The rating plate is located on the right side of
the unit, above the power cord. 

TABLE 1

Suggested Individual Branch Circuit

Nameplate Amps

*AWG Wire Size

4.9 to 10

14

AWG- American Wire Gauge

*Based on copper wire at 60°C temperature rating.

TABLE 2

Receptacle and Fuse Types

Rated Volts

125

Amps

15

Wall Outlet

Fuse Size

15

Time Delay Fuse

Plug Type

(or Circuit Breaker)

PART IDENTIFICATION

IMPORTANT SAFETY INFORMATION

ELECTRICAL

SPECIFICATIONS

Fresh Air Ventilation Switch

(open for Fan only operation)

Cabinet

Exterior air

inlet

Filter

Interior air

outlet

Interior air

inlet

Control

Panel

2

Summary of Contents for DAC10010E

Page 1: ...doit tre inclus avec l appareil CAUTION Read and follow all safety rules and operating instructions before first use of this product MISE EN GARDE Veuillez lire attentivement les consignes de s curit...

Page 2: ...rough the wall installation For easy reference may we suggest you attach a copy of your sales slip receipt to this page along with the following information located on the manufacturers nameplate on t...

Page 3: ...wall outlet must match the 3 prong plug on the service cord supplied with the unit DO NOT use plug adapters See Table 2 for receptacle and fuse information If it is necessary to use an extension cord...

Page 4: ...talling or servicing 3 4 19 1mm screws 9 Factory installed on some models Safety Lock 1 Adhesive Foam Seal 1 Sash bracket 2 L Shaped mounting bracket 1 INSTALLATION HARDWARE Your Room Air Conditioner...

Page 5: ...tain the proper electrical outlet is within reach of the installation Use only a single outlet circuit rated at 15 amps All wiring should be in accordance with local and national electrical codes F DO...

Page 6: ...each side and secure the top of the frames to the window sash using one 3 4 screw on each side and one in the L shaped mounting bracket Fig 5 Secure the shutter clamp on each side of the lower shutter...

Page 7: ...ration SLEEP MODE When activated the current set temperature is gradually increased over a one 1 hour period then maintained for seven 7 hours Once the program is complete the air conditioner will res...

Page 8: ...nds in order to set the clock Press the increase or decrease arrow to adjust the clock in 1 minute intervals holding down the increase or decrease arrow will adjust the time in 10 minute intervals 10...

Page 9: ...Dry thoroughly before re installing CLEANING AIR FILTER 1 Use a vacuum cleaner with soft brush attachment 2 Wash the filter in lukewarm water below 40 C 104 F To get best results wash with soapy water...

Page 10: ...inappropriate for application Blocked air flow Power interruption settings changed too quickly or compressor overload tripped Clean replace air filter Check with dealer to determine proper unit capac...

Page 11: ...de l appareil Inscrivez les renseignements suivants fournis sur la plaque signal tique du fabricant sur le c t droit de l appareil au dessus du cordon d alimentation Vous aurez besoin de ces renseigne...

Page 12: ...ien qualifi 5 La prise murale doit correspondre la fiche 3 broches sur le cordon de service fourni avec l appareil N utilisez PAS de fiches d adaptation Voir Tableau 2 pour les renseignements sur les...

Page 13: ...droit ce c t est plus lourd et plus difficile manipuler Un soutien inappropri du c t des commandes de l appareil peut causer des blessures et endommager l appareil et d autres biens mobiliers C est po...

Page 14: ...pi ce puissent bloquer le flux d air E Assurez vous que la prise lectrique appropri e se trouve la port e de l installation N utilisez qu un circuit prise unique calcul 15 amp res Tout le c blage doi...

Page 15: ...s volets compl tement de chaque c t et fixez le haut des structures au cadre de la fen tre en utilisant une vis de 3 4 po et une rondelle de s curit sur chaque c t Fig 5 Coupez la bande mousse adh sif...

Page 16: ...meil Le mode de sommeil augmentera votre temp rature de climatisation pr r gl e graduellement pendant une p riode de un 1 heures la nouvelle temp rature est maintenue pendant sept 7 heures Une fois qu...

Page 17: ...et la t l commande pourrait causer une interf rence au signal ce qui limiterait la capacit de programmation de l unit principale Affichage lectronique 17 7 Annuler le programme Minutrie en Marche et...

Page 18: ...lisez un aspirateur de poussi re muni d une brosse douce 2 Lavez le filtre dans de l eau ti de de moins de 40 C 104 F Pour obtenir de meilleurs r sultants lavez avec une eau savonneuse ou un agent neu...

Page 19: ...ement ou compresseur d clench par surcharge Nettoyez ou remplacez le filre air Verifiez avec le concessionnaire si la capacit de l appareil est appropri e son application Enlevez l objet qui obstrue l...

Page 20: ...you call the TOLL FREE NUMBER When requesting service or ordering parts always provide the following information Product Type Model Number Part Number Part Description CLIMATISEUR Le num ro de mod le...

Reviews: