79
7.7
M
ANUFACTURER SPECIFIC FUNCTION
C
ODES
7.7.1
Command functions
Modbus allows a block of function codes to be assigned by the manufacturer. The S200
Position Node product has chosen to implement the following function codes.
7.7.2
Command Execution: FC 65
The following model is the general form of the commands. Function Code 65 and the
command ID request triggers the execution of a command function (see table below).
Transmit the command to the S200 Position Node:
UA=xx
FC=65 command id CRC
Response Received from the S200 Position Node:
UA=xx FC=65 command id CRC
The defined commands are:
Command
Id
Save Parameters Non-volatile memory
1
Restore Parameters from Non-Volatile Memory
2
Set all parameter to factory default settings
3
Enable Drive
12
Disable Drive
13
Coldstart Drive (Reset)
14
Reset Faults and Warnings
15