![Danaher Motion S20630 Installation Manual Download Page 64](http://html1.mh-extra.com/html/danaher-motion/s20630/s20630_installation-manual_3356509064.webp)
58
4.7
S200 B
ASE
U
NIT
F
AULTS
(
B
-
FAULTS
)
As previously stated the base unit Status LED will flash a code if the drive is in
a faulted condition. The following table explains the fault code.
Flash Count
Status
Resulting Drive Action
Reset Method
1
No Fault drive disabled
Normal Operation
2
Motor Over Temp sensor has
tripped
Drive Disabled with fault Clear Fault input, Disable/Enable, Coldstart, GUI
‘Drive Reset’ Button, or Cycle Power
3
Drive Over/Under Temp
Drive Disabled with fault
Clear Fault input, Disable/Enable, Coldstart, GUI
‘Drive Reset’ Button, or Cycle Power
4
Drive I*t Too High; Exceeded
RMS ratings of the drive.
Drive Disabled with fault
Clear Fault input, Disable/Enable, Coldstart, GUI
‘Drive Reset’ Button, or Cycle Power
5
Motor I*I*t Too High; Exceeded
RMS ratings of the motor.
Drive Disabled with fault
Clear Fault input, Disable/Enable, Coldstart, GUI
‘Drive Reset’ Button, or Cycle Power
6
Reserved
7
Bus Over Voltage; Mains high-
line or excessive regeneration.
Drive Disabled with fault
Clear Fault input, Disable/Enable, Coldstart, GUI
‘Drive Reset’ Button, or Cycle Power
8
Bus Under Voltage
Drive Disabled with fault
Clear Fault input, Disable/Enable, Coldstart, GUI
‘Drive Reset’ Button, or Cycle Power
9
Motor l-l or l-n Short
Drive Disabled with fault
Clear Fault input, Disable/Enable, Coldstart, GUI
‘Drive Reset’ Button, or Cycle Power
10
Output Over Current
Drive Disabled with fault
Clear Fault input, Disable/Enable, Coldstart, GUI
‘Drive Reset’ Button, or Cycle Power
11
Hall Fault
Drive Disabled with fault
Clear Fault input, Disable/Enable, Coldstart, GUI
‘Drive Reset’ Button, or Cycle Power
12
SFD Configuration Error
Drive Disabled with fault
Clear Fault input, Disable/Enable, Coldstart, GUI
‘Drive Reset’ Button, or Cycle Power
13
SFD Short
Drive Disabled with fault
Clear Fault input, Disable/Enable, Coldstart, GUI
‘Drive Reset’ Button, or Cycle Power
14
SFD Motor Data Error
Drive Disabled with fault
Clear Fault input, Disable/Enable, Coldstart, GUI
‘Drive Reset’ Button, or Cycle Power
15
SFD Sensor Failure
Drive Disabled with fault
Clear Fault input, Disable/Enable, Coldstart, GUI
‘Drive Reset’ Button, or Cycle Power
16
SFD UART Error
Drive Disabled with fault
Clear Fault input, Disable/Enable, Coldstart, GUI
‘Drive Reset’ Button, or Cycle Power
17
SFD Comm Error
Drive Disabled with fault
Clear Fault input, Disable/Enable, Coldstart, GUI
‘Drive Reset’ Button, or Cycle Power
18
Option Card Watch Dog Time
out
Drive Disabled with fault
Clear Fault input, Disable/Enable, Coldstart, GUI
‘Drive Reset’ Button, or Cycle Power
19
PosErr Too Large
Drive Disabled with fault
Clear Fault input, Disable/Enable, Coldstart, GUI
‘Drive Reset’ Button, or Cycle Power
20
Table 4.3: Base Unit Fault Table
Summary of Contents for S20630
Page 6: ......
Page 15: ...9 3 1 6 E 6 E 6 E 6 E 6 E 6 E 6 E 6 E...
Page 19: ...13 1 6 11 General 3H 3 3H 5 E 3 3 5J...
Page 94: ......