Signal Levels
Analog
The Model E-1A requires line level signals in the range -20 to +4 dBm; 0 dBm is optimal.
The
level
LEDs light green for normal operation and red for overload.
If there is insufficient gain to keep the
level
LEDs lit green when no one is talking, set
the rear panel
LEVEL
switch to
-10
.
Digital
Set the console input gain trimmers so program levels at the insert sends cause the
level
LEDs to remain green whether someone is talking or not.
Linking Multiple Dugans
Up to eight Dugan units can be linked into a single automatic mixing system. One
unit must be set to be the master and the others slaves.
Figure 3-6
Linking multiple Dugans
1.
Designate one unit as the master by setting the
NORM-SLAVE
switch on the rear
panel to
NORM
(up).
2.
Designate any other units as slaves by setting their
NORM-SLAVE
switches on the
rear panel to
SLAVE
(down).