Dugan Models E-1 and E-1A User Guide
Quickstart
13
To execute a power-up Reset command, hold the channel 1
bypass
button down dur-
ing power-up. This sets all parameters to factory default settings and clears label text.
We recommend executing a Reset command (just like “zeroing out” a console) before
starting a new installation.
Linking Multiple Dugans
Up to eight Dugan units can be linked into a single automatic mixing system. One
unit must be set to be the master and the others slaves.
Figure 2-3
Linking multiple Dugans
1.
Designate one unit as the master by setting the
NORM-SLAVE
switch on the rear
panel to
NORM
(up).
2.
Designate any other units as slaves by setting their
NORM-SLAVE
switches on the
rear panel to
SLAVE
(down).
3.
Use ADAT (Toslink) cables to link units in a ring network (see above).
Note that all
LINK IN
and
OUT
connectors are used to create the ring.
NOTE:
Due to the Model E-1A’s compact size and close spacing of the ADAT connectors, some large
cables may not fit. The maximum cable width is 0.48 in (12 mm).
NOTE:
Linked Model E-1s appear in group a only. Linked Model E-1As can use groups a–c.