background image

 

Serie "LXS9"

 

 
 

 

Pagina A - 21 

 

Rev. M - 01 

Summary table:  

(*) Memorandum to be filled out after the programming under way

 

Menu 

Parameter 

Meaning 

Min-Max 

Default 

Adjusted 

to (*)

 

General Param’s

  Language 

Message language 

 

Italian 

 

General Param’s

  Operating mode 

Operating mode 

 

MDB 

 

General Param’s

  DDD DD/mm hh:mm 

Clock setting 

 

General Param’s

 

DateTime Dsp 
Enable 

Clock enable 

Enabled - 
Disabled 

Enabled 

 

General Param’s

  SaveMode delay 

Activation delay in SaveMode 

0 ÷ 120 minutes 

 

General Param’s

  Light in SaveMode 

Light intensity in SaveMode 

0 ÷ 100% 

100% 

 

General Param’s

 

NightMode 
timetable 

NightMode Activation 
Timetable 

 

19:00÷7.00 

 

General Param’s

  NightMode Light 

Light intensity in NightMode 

0 ÷ 100% 

100% 

 

General Param’s

  NightMode temp. 

Temperature setting in 
NightMode 

0 ÷ 50 °C 

 

General Param’s

 

Refrigerator 
operation 

Refrigerator Operation 

 

Aut. 

 

General Param’s

  FTCA enabling 

Vending sensor enabling 

0)Disabled, 
1)Enable Nostep, 
2)3step 

2) 

3step 

 

General Param’s

  FTCA max 3 sel. 

FTCA max 3 selections 

Enabled - 
Disabled 

Enabled 

 

General Param’s

  Decimal point 

Decimal point position 

0 ÷ 3 

 

General Param’s

  Code Mode 

Internal code software 

Read only

 

General Param’s

  Software versions 

Displays software versions 

 

General Param’s

  Default P. Reset 

Card reinitialisation 

Password required

 

General Param’s

  Protected param. 

Protected parameters 

Password required

 

 

Reset Temp. 

--- 

Reinitialise overtemperature times 

 

 

 

 

 

 

Price management  Price-A N.:xx 

Value of each of the 44 
associable „A‟ bracket prices 

0 ÷ 635.35 

2.00 

----

 

Price management  Price-B enabling 

Enabling „B‟ price bracket 

Enabled - 
Disabled 

Disabled 

 

Price management  Price-B N.:xx 

Value of each of the 44 
associable „B‟ bracket prices 

0 ÷ 635.35 

2.00 

----

 

Price management  Drawer L-C 

Price associated with drawer 
(Line) 

L

, (column) 

C

 

0 ÷ 44 

01

 

----

 

Price management  Enable Price Dsp 

Display of the selling price 

Enabled - 
Disabled 

Enabled 

 

 

Executive 
parameters 

Min. coin values 

Coin scaling factor 

0 ÷ 1000 

000.01 

 

 

MDB parameters 

Maximum credit 

Maximum accepted credit 

0 ÷ 635.35 

 

MDB parameters 

MinTube NoChange 

Minimum coins to turn “

no 

change

” indicator light on 

 

 

MDB parameters 

MinTube Change  

Minimum coins for giving 
change 

 

 

MDB parameters 

Obligatory Sale 

Compulsory sale 

Enabled - 
Disabled 

Disabled 

 

MDB parameters 

Enab. Man. 
Dispens 

Manual emptying of the coin 
tubes 

Enabled - 
Disabled 

Disabled 

 

MDB parameters 

Sale Modalit. MDB 

MDB sales modes 

0)Single no Chang 

1)Change 

2)Multi Vend 

1) 
Change 

 

 

Summary of Contents for LXS9 Series

Page 1: ...X INSTALLATION AND SERVICE PROGRAMMING This manual is for skilled service personnel only DAMIAN S R L VIA RAGAZZI DEL 99 N 30 21053 CASTELLANZA VA ITALY Rev M 01 Vers Software 1 1a or follow...

Page 2: ...Serie LXS9 Pagina A 25 Rev M 01...

Page 3: ...ed use for LXS9 series LUCE X SNAC automatic spiral vending machines consists of automatically distributing solid products or products in solid package pre packaged foods snacks bottled drinks etc and...

Page 4: ...stem version Absent Super Minimum internal operating temperature 2 C Food zone only Environment Storage temperature 0 45 C Working temperature 5 32 C Max relative humidity 65 Dimensions and Weights He...

Page 5: ...hildren should be supervised to make sure that they do not play with the vending machine Before checking any electrical part move the main switch of the vending machine See Figure 2 to the OFF positio...

Page 6: ...them rest correctly on the ground When the vending machine is not levelled properly it can be difficult to close the door With the wall anchoring bracket kit accessory it is possible to anchor the ve...

Page 7: ...d service personnel Before all operations on the power cord make sure that the power supply plug is disconnected from its outlet Remove the rear grille of the cabinet by unscrewing its fixing screws r...

Page 8: ...ation of the executive payment systems Connect the Molex 15 pin female power connector of the vending machine to the corresponding connector on the payment system Refer to the payment system documenta...

Page 9: ...iding panel motor 18 Sliding panel motor pinion 5 Two magnets for locking the Push door 12 Door open switch 6 Two microswitches of the Push locking magnets 13 Two beginning end stroke microswitches 19...

Page 10: ...time B is prolonged by a value equal to the one set in the Restocking time C parameter Each time it is turned back on if the internal temperature exceeds the Safety temperature A but the conditions f...

Page 11: ...probe has been replaced the problem is repeated the fault might be due to the CLP1 power board located in the electrical box OFF L02 Temperature probe 2 error These messages indicate a problem with th...

Page 12: ...Sliding door test as explained further on OFF L12a Door Push EMagnet Fault Magnets for locking the Push door short circuited One or both magnets 5 for locking the door are short circuited Check their...

Page 13: ...fter maintenance Check that the panel motor 11 power supply connection has not been inverted OFF L13e TimeOut SD Mot Sliding panel error during opening At the end of an opening cycle the sliding panel...

Page 14: ...gnostic tests some motor anomaly messages might appear on the display these messages are listed below with the relative explanation as well as some possible solutions to the problem Motor xx Disconnec...

Page 15: ...LAYED During normal vending machine operation some malfunctions of some motors may occur These malfunctions generate errors that can be automatically reset by the vending machine R or that can be not...

Page 16: ...motors function is not activated If the problem persists make sure that the CPU card works and replace it if necessary THE MACHINE DOES NOT REACH THE REQUIRED TEMPERATURE Before carrying out any oper...

Page 17: ...and disconnect the power supply wiring of the refrigerator from the electrical box Grasp the handle e at the base of the refrigeration unit and remove it from the normal work position by pulling it if...

Page 18: ...te B F2 5x20 T6 3 6 3 A delayed 250 V General 24 28V The vending machine does not work C F3 5x20 T6 3 6 3 A delayed 250 V General 230V The vending machine does not work D F4 5x20 T6 3 6 3 A delayed 25...

Page 19: ...that it turns on again only after it has been closed completely SLIDING PANEL CHECK AND LUBRICATION Sliding panel 10 operation can be checked by performing a door closing and opening test see programm...

Page 20: ...roswitches and that the magnets can move freely After having reassembled the magnet covering panel perform a door closing and opening test see programm diagnostics Product door test CHECK CLEANING OF...

Page 21: ...nctions provided for by the regulations in force 1 In the European Union If the equipment is marked on the outside with this symbol it should not be disposed of with normal household waste Contact you...

Page 22: ...Serie LXS9 Page 21 Rev M 01...

Page 23: ...tachment A PROGRAMMING SHEET This attachment is an integral part of the manual and must remain with it DAMIAN S R L VIA RAGAZZI DEL 99 N 30 21053 CASTELLANZA VA ITALY Rev M 01 Vers Software 1 1a or fo...

Page 24: ...ain from the first parameter When the message relative to the desired parameter appears press the F Enter key to confirm TO CHANGE THE PROGRAMMED VALUE OF THE SELECTED PARAMETER If appears on the seco...

Page 25: ...ght Kit installed Energy Saving allows activating two separate energy saving functions Save Mode function Kicks in after a programmed vending machine inactivity time and reduces the electrical consump...

Page 26: ...Vivilight Kit installed This parameter allows setting the luminous intensity in of the LED lamps that light up the display window when the Night Mode function is activated Settable values 0 100 Defaul...

Page 27: ...il or if the 3 step function is not active the vending machine still keeps the credit stored in memory and allows a new selection to be made When this function is selected it will be possible to set t...

Page 28: ...appears on the display after selecting the desired language press F to confirm B This message appears on the display Check that the number of connected motors corresponds to those actually present in...

Page 29: ...ending machine returns to the programming menu No other modes can be selected If the value is 1 One there is just one refrigerator probe connected the following message will appear when the F key is p...

Page 30: ...back below the set threshold in the residual time remaining To prevent false out of order indications after prolonged operator intervention the various counters can be initialised through this functi...

Page 31: ...F key to select the value VVVVV of the price line to be varied Enter the new value pressing the numbers on the keyboard confirm the price by pressing the F key again Note if the entered value is not...

Page 32: ...0 65535 independent of the position of the comma e g with 2 decimals the maximum credit is 655 35 If set to 0 this control is disabled Default 0 COIN RETURN PARAMETERS If there is an MDB coin return...

Page 33: ...machine it will be possible to set the reading and or recognition of the quantity and or value of coins or tokens present in the coin box tubes The following coin and tube parameters can be set by sel...

Page 34: ...alue of the banknote Secur H recognition security level high Secur L low Enabl ON banknote enabled Enabl OFF banknote disabled Press F to enable disable the banknote press C to change the recognition...

Page 35: ...m is installed To set the parameters of the RFID payment system RFID PRICE BRACKET If an RFID payment system is installed in the vending machine it allows selecting the price bracket to be associated...

Page 36: ...erature control section and the description of the ERR L09 error message for the description Settable values 0 45 C To deactivate this function set it to 40 C Default 45 C OVERTEMPERATURE TIME Visible...

Page 37: ...nnection with a handheld device that has a code other than 0 set AUDIT PARAMETERS NOTE It is possible to display a minimum list of sales data on the automatic vending machine If an MDB system is insta...

Page 38: ...y using the appropriate keys OUT OF ORDER MOTORS Select this item to see which motors have generated an Out of Order condition The out of orders are also listed in this menu The following message will...

Page 39: ...tivated the following message will appear if a malfunction occurs Where xxxxxx is the detected error See the Installation and service manual Problems and relative solutions chapter Motor anomaly messa...

Page 40: ...ad that anomalies and or differences between the current configuration and the one detected during the self learning procedure have not been detected XX indicates the number of the recognised motors I...

Page 41: ...5 induce a good efficency of the motor X and Y values inferior to 5 induce a low efficency of the motor Motor works as well but it is necessary to make the following controls in order to avoid future...

Page 42: ...one of the three parameters should be at the ERR level the FTCA infrared system will be out of order and an OFF L10 message will be displayed see OFF message table for details When the following messa...

Page 43: ...nternal code software Read only General Param s Software versions Displays software versions General Param s Default P Reset Card reinitialisation Password required General Param s Protected param Pro...

Page 44: ...30 Refrig Param s Refueling time Restocking time 0 1000 min 120 Refrig Param s Connected probes Number of connected refrigerator probes Read only EVA DTS parameters Reset passcode Reset Security and P...

Page 45: ...EN 61000 3 3 1995 A1 2001 A2 2005 EN 50366 2003 A1 2006 e soddisfa i requisiti essenziali della Direttiva 98 37 CE Declares that the machine described on the identification plate is in conformity wit...

Page 46: ...relative to the installation and connection of the device to the power supply systems are not included in the warranty either Damian S r l is not responsible for possible injuries and damage to person...