Serie "LXS9"
Page 14
Rev. M - 01
“
Motor xx Max 3 Selec Err.
” (R)*: The motor has been put out of order after three consecutive sales of
the same motor without detecting that the product has dropped
(See “FTCA Parameters” chapter).
Check that the spiral is hooked correctly to the motor.
Check the operation of the product drop control sensors (See “Diagnostics” chapter).
* = The error is automatically reset (R) or not reset (NR) upon turning on.
-
U
PON TURNING ON
“O
FF
L13b (SD
M
OT
.
D
ISCONN
)”
IS DISPLAYED
.
When the vending machine is turned on, you can not perform the test open / close of the sliding panel
because the motor is not connected.
This error can occur even if you are attempting to make the sliding panel motor work with the door open
when the open door switch (12) is not activated. Close the door or arm the switch, pulling the lever
outwards, to simulate the closed door.
If the door is closed, check the operation of the door open switch (12) and the relative wiring. Also check
that the bracket (14) that presses the switch is adjusted properly. Replace the switch or the bracket if
necessary.
Check the motor (11) of the sliding panel (10) and the relative wiring. Replace it if necessary.
-
U
PON TURNING ON
“A
TTENZ
.
VERIFICA PANNELLO SCORREV
.”
IS DISPLAYED
.
When the vending machine is turned on, during the test of opening and closing the sliding panel, and
wrong opening and closing times of the sliding panel values are found, it is suggested to perform a
calibration of these values.
To calibrate sliding panel
time/speed of opening/closing, enter into “Diagnostic” in the “
Sliding panel test
”
menu (see relative chapter).
-
U
PON TURNING ON
“W
ARNING OUT OF ORDERS DETECTED
”
IS DISPLAYED
.
During normal vending machine operation, some malfunctions of some motors may occur. These
malfunctions generate errors that can be automatically reset by the vending machine (R)* or that can be
"not resettable" (NR)* and put the selection out of order (see above).
Even if operation of the selection has been automatically reset when the machine was turned on, the error
remains stored and must be deleted manually in diagnostics to keep the message from reappearing.
To check which motors and which problems have been stored, enter into “Diagnostic” in the “
out of order
motors
” menu (see relative chapter).
-
W
HEN MAKING A SELECTION
“S
ELEC
.
X
-
X IN OVERTEMPERATURE
”
IS INDICATED
If some s
elections are out of order indicated by the “
Selection xx in Overtemperature
” message, this is due
to the intervention of the “refrigerator safety control” (ERR L09 refrigeration unit timeout error) which has
put the drawers set in the vending machine
„Food zone‟ out of order (see Overtemperature control”
section).
Entering in programming, you will be asked if you wish to restore operation by resetting the error.
Press key
1
to reset the error
Press key
2
to NOT reset the error
When key
1
is pressed the selections will be active again.
-
W
HEN MAKING A SELECTION
“S
ELECTION X
-
X NOT ACTIVE
”
IS INDICATED
If some selections are out of order indicated by the “
Selection x-x not active
” message, this indicates a
problem relative to the storing of the configuration, because the selection made is not stored as active by
the vending machine.
Make sure that you have made the correct selection.
Carry out the “
Motor Verify
” procedure found in the diagnostic menu.
Carry out a new self-learning procedure of the motors through the reset of the circuit board.
If the motor is not recognised during the self-learning procedure, see the relative error further on.
Reset ERR L09
(1):YES (2):NO