Serie "LXS9"
Page 12
Rev. M - 01
Message
code
Message text
Problem description / solution
OFF L13… Sliding anti-theft panel errors.
These error messages concern failures of the sliding anti-theft panel
(10) closing/opening system.
OFF L13a
Sliding Panel
(S.D. Mot. Fault) - Sliding panel motor short-circuited
- Check the operation of the sliding panel motor (11) and the relative wiring; replace
it if necessary.
OFF L13b
(SD Mot. Disconn.) -
Sliding panel motor disconnected
- You are attempting to make the sliding panel motor work with the door open when
the open door switch (12) is not activated. Close the door or arm the switch to
simulate the closed door.
- If the door is closed, check the operation of the door open switch (12) and the
relative wiring. Also check that the bracket (14) that presses the switch is adjusted
properly. Replace the switch if necessary.
- Check the motor (11) of the sliding panel (10) and the relative wiring. Replace it if
necessary.
OFF L13c
(Sl.Door Removed) - Sliding panel removed
Neither of the 2 beginning/end stroke microswitches (13) located near the motor are
pressed.
- Check that the sliding panel has been put back on after maintenance.
- Check the operation of the 2 beginning/end stroke microswitches (13) and the
relative wiring. Replace them if necessary.
OFF L13d
(Switch Exchanged) - Sliding panel microswitches inverted
The CPU card (2) receives the closing signal when the motor (11) opens the sliding
door (10) and vice versa.
- Check that the beginning/end stroke microswitches (13) have been connected
correctly after maintenance.
- Check that the panel motor (11) power supply connection has not been inverted.
OFF L13e
(TimeOut SD Mot.) - Sliding panel error during opening
At the end of an opening cycle, the sliding panel does not open completely or is not
detected to be open.
- Check that the sliding panel (10) can slide freely, that the guides are clean and that
there is nothing preventing complete opening.
- Check the operation of the opening microswitch (13) and the relative wiring.
Replace it if necessary.
OFF L13f
(TimeOut SD Mot.) - Sliding panel error during closing
At the end of an opening / closing cycle, the sliding panel does not close completely
or is not detected to be closed.
- Check that the sliding panel (10) can slide freely, that the guides are clean and that
there is nothing preventing complete closing.
- Check the operation of the closing microswitch (13) and the relative wiring.
Replace it if necessary.
OFF L13g
(SD Mot Movement)
– Sliding panel motor movement error
You are trying to make the sliding panel (10) work but the motor (11) idles or is
blocked.
- Check that the motor block of the panel is hooked correctly.
- Check that the motor gear (11) works correctly.
- Check that the sliding panel (10) can slide freely.
OFF L20… CL1 CPU (2) circuit board errors.
These error messages concern failures of the
vending
machine
‟s circuit board.
OFF L20a
OFF L20b
CL1 CPU Error
(Restart - Change) - CPU card error
- Turn the vending machine off and then on again; if the problem persists, replace
the CPU card (2).
OFF L20f
OFF L20g
CL1 CPU SW Error (Reinstall SoftW.) -
CPU card software error
- Turn the vending machine off and then on again; if the problem persists, update
the software.
- If the problem is not resolved after the update, replace the CPU card (2).