Serie "LXS9"
Pagina A - 4
Rev. M - 01
»
S
AVE
M
ODE
-
A
CTIVATION DELAY
:
(Visible and programmable only with Vivilight Kit installed)
This parameter allows setting the time in minutes that must elapse, without anyone using the vending
machine, before the
Save Mode
function is activated (attenuation of the intensity of the LED lamps).
Settable values:
0
÷ 120
minutes.
Set the parameter to Zero „
0
‟ to deactivate the function.
[ Default: 0 minutes]
»
S
AVE
M
ODE
-
L
IGHT INTENSITY
:
(Visible and programmable only with Vivilight Kit installed)
This parameter allows setting the luminous intensity (in %) of the LED lamps that light up the display
window when the Save Mode function is activated.
Settable values:
0 ÷ 100%
.
[ Default: 100% ]
»
N
IGHT
M
ODE
-
T
IMETABLE
:
(Visible and programmable only with Vivilight Kit installed)
This parameter allows setting the start and end times of the
Night Mode
function.
Set the times to
00:00
-
00:00
to disable the function.
[ Default: 19:00
– 07:00 ]
»
N
IGHT
M
ODE
-
L
IGHT INTENSITY
:
(Visible and programmable only with Vivilight Kit installed)
This parameter allows setting the luminous intensity (in %) of the LED lamps that light up the display
window when the
Night Mode
function is activated. Settable values:
0 ÷ 100%
.
[ Default: 100% ]
»
N
IGHT
M
ODE
-
I
NTERNAL TEMPERATURE SETTING
:
(Visible and programmable only with Vivilight Kit installed and “
Refrigerator
operation” other than “Food & Snack”)
This parameter allows setting the internal temperature of the vending machine when the
Night Mode
function is activated.
Settable values:
0 ÷ 50°C
.
[ Default: 0°C ]
The refrigerator temperature raising function is deactivated during the
Night-Mode
period if the
parameter is set to „
0
‟ (Zero) or to a value below the one set as standard internal temperature („
Set Std
Temp 1
‟ in the “
Refrig. Param‟s
” menu).
This parameter can also be programmed through the
“
Refrig. Param‟s
” menu.
Programming
General param.
Energy Saving
->->->
SaveMode delay
Current value
F
F
Programming
General param.
Energy Saving
->->->
Light in SaveMod
Current value
F
F
Programming
General param.
Energy Saving
->->->
Night Mode times
hh:mm – hh:mm