62
Spyder2 4k User’s Manual
03-032-10195-04
DALSA
Error Codes
Cod
e
Description
Suggested Cause
9
Start value must be an odd
number less than the even
numbered end value
roi
: invalid starting or ending pixel index
10
Camera memory check failure
Memory test of external RAM failed
11
Unable to configure DSP
DSP (FPGA) configuration failure
12
DSP configuration reset failure
DSP (FPGA) could not be placed in
configuration mode
13
Get line process command timed
out, check for the presence of
external signals
gl
,
gla
,
cao
,
cag
,
ccf
,
ccp
timed out.
Current exposure mode requires external
SYNC, however SYNC signal not present
14
DSP echo test error
DISC bus communication test failure
15
Invalid sensor configuration
(DSP)
Invalid sensor configuration read from DSP
(FPGA)
16
Invalid sensor configuration
(ADC)
Invalid sensor configuration encoding on
the board
17
Sensor configuration mismatch
Sensor configuration read from DSP is
different than one encoded on the board
18
One (or more) of the supply
voltages is out of specification
vv
command result
19
The camera's temperature is
outside the specified operating
range
vt
command result
20
Not Used
Not Used
21
Analog offset calibration failure
Analog offset calibration failure (could not
tune the analog offset to obtain targeted
video level)
22
Analog gain calibration failure
Analog gain calibration failure (could not
tune the analog gain to obtain targeted
video level)
23
CRC check failure while
attempting to restore the camera
settings
Camera setting will initialize to default
settings, since restore of USER/FACTORY
settings failed (internal micro EE memory
failure). Contact your DALSA
representative or Product Support if this
error code is returned.
24
Camera settings not saved
rus
,
rfs
attempted but settings were not
saved. Contact your DALSA representative
or Product Support if this error code is
returned.
25
Pixel coefficients write failure
Failure while writing pixel coefficients to
EEROM (I2C EEROM external to micro)
26
I2C communication fault while
accessing temperature sensor
Serial communication fault (I2C) while
accessing temperature sensor
27
Timeout waiting for DISC SYNC
to go LOW
Internal communication protocol error
28
Unable to calibrate gain. Tap
Analog gain could not be calibrated because
Summary of Contents for Spyder2 S2-2x-04K40
Page 10: ...10 Spyder2 4k User s Manual 03 032 10195 04 DALSA ...
Page 38: ...38 Spyder2 4k User s Manual 03 032 10195 04 DALSA ...
Page 52: ...52 Spyder2 4k User s Manual 03 032 10195 04 DALSA ...
Page 56: ...56 Spyder2 4k User s Manual 03 032 10195 04 DALSA ...
Page 74: ...74 Spyder2 4k User s Manual 03 032 10195 04 DALSA ...
Page 76: ...76 Spyder2 4k User s Manual 03 032 10195 04 DALSA ...