21
Spyder2 4k User’s Manual
03-032-10195-04
DALSA
3.4 Startup
When the camera is first started, it must perform several actions before it is ready for
imaging. This startup routine takes approximately 15 seconds, and follows this sequence:
1.
Initializes the camera and all internal hardware.
2.
Loads the last settings saved to non-volatile memory, including the last set of video
correction coefficients, if previously saved.
3.
Restores user settings if previously saved, otherwise factory settings.
4.
Performs a memory test and voltage test and reports an error if any occurred.
After this startup sequence is complete, the camera will return either the prompt "OK>" if
no error occurred, or an error code if a problem has been discovered.
3.5 Saving and Restoring Settings
The camera provides a number of commands for restoring, storing, and saving settings.
To restore the original factory settings, use the command
rfs
. The FPN and PRNU
coefficients are reset to 0.
To save all current settings to EEROM, use the command
wus
. The camera will
automatically restore the saved user settings when powered up.
Note:
While settings
are being written to nonvolatile memory, do not power down camera or camera
memory may be corrupted.
•
To save all current pixel coefficients to EEROM, use the command
wpc
.
•
To restore the last saved user settings and the FPN and PRNU coefficients, use the
command
rus
.
write / restore
restore
Current
Session
Factory
Settings
User Settings /
EEROM
Summary of Contents for Spyder2 S2-2x-04K40
Page 10: ...10 Spyder2 4k User s Manual 03 032 10195 04 DALSA ...
Page 38: ...38 Spyder2 4k User s Manual 03 032 10195 04 DALSA ...
Page 52: ...52 Spyder2 4k User s Manual 03 032 10195 04 DALSA ...
Page 56: ...56 Spyder2 4k User s Manual 03 032 10195 04 DALSA ...
Page 74: ...74 Spyder2 4k User s Manual 03 032 10195 04 DALSA ...
Page 76: ...76 Spyder2 4k User s Manual 03 032 10195 04 DALSA ...