35
Spyder2 4k User’s Manual
03-032-10195-04
DALSA
To read the FPN coefficient, use the command:
Syntax:
gfc
i
Syntax Elements:
i
The pixel number to read.
Example:
gfc 10
3.16 Setting and Reading PRNU Coefficients
You can set or read an individual pixel’s PRNU coefficient.
To set the PRNU coefficient, use the command:
Syntax:
spc
i i
Syntax Elements:
i
The pixel number from 1 to the pixel count.
i
Coefficient value in a range from 0 to 511 where:
512
1
i
PixelPRNU
+
=
Example:
spc 10 50
To read the PRNU coefficient, use the command:
Syntax:
gpc
i
Syntax Elements:
i
The pixel number to read.
Example:
gpc 10
3.17 Generating Test Patterns
The camera can generate a test pattern to aid in system debugging. Use the command
svm 2
to activate the test pattern. The test pattern is a ramp from 0 to 255 DN, then starts
at 0 again. Use the test pattern to verify the proper timing and connections between the
camera and the frame grabber.
End-of-line Sequence
To further aid debugging, the camera can generate an end-of-line sequence. The end-of-
line-sequence outputs "aa", "55", "aa", "line counter", "line average", "pixels above
threshold", "pixels below threshold", "derivative line sum". To activate the end-of-line
Summary of Contents for Spyder2 S2-2x-04K40
Page 10: ...10 Spyder2 4k User s Manual 03 032 10195 04 DALSA ...
Page 38: ...38 Spyder2 4k User s Manual 03 032 10195 04 DALSA ...
Page 52: ...52 Spyder2 4k User s Manual 03 032 10195 04 DALSA ...
Page 56: ...56 Spyder2 4k User s Manual 03 032 10195 04 DALSA ...
Page 74: ...74 Spyder2 4k User s Manual 03 032 10195 04 DALSA ...
Page 76: ...76 Spyder2 4k User s Manual 03 032 10195 04 DALSA ...