Figure 28. CamExpert’s Camera Information Window
Verify Temperature and Voltage
To determine the voltage and temperature at the camera, use the
Refresh Voltage and Refresh
Temperature
features found in the
Camera
Information
set.
The temperature returned is the internal temperature in degrees Celsius. For proper operation, this value
should not exceed 80 °C. If the camera exceeds the designated temperature it will stop imaging and the
LED will turn red. Once you have diagnosed and remedied the issue use the
reset camera
function.
The voltage displayed is the camera’s input voltage.
Note:
The voltage measurement feature of the camera provides results typically within 1%. This
measurement can be used to set the applied voltage to the camera.