![Dalsa Piranha4 Series Manual Download Page 33](http://html.mh-extra.com/html/dalsa/piranha4-series/piranha4-series_manual_504408033.webp)
Piranha4 2K and 4K Color Camera User's Manual
33
Teledyne DALSA
03-032-20180-06
Data connector: Camera Link
The camera uses two Camera Link SDR26 cables transmitting the Camera Link Base, Medium, Full, or
Deca configuration. The figure below shows the SDR26 Camera Link Connector and the tables that follow
list the Camera Link configurations.
For detailed information on Camera Link please refer to the Camera Link Road Map available from the
on the Teledyne DALSA Web site.
Figure 23. SDR26 Camera Link Connector
Data 2
Control / Data 1
Camera
Connector
Right Angle
Frame Grabber
Connector
Channel Link
Signal
Camera
Connector
Right Angle
Frame Grabber
Connector
Channel Link
Signal
1
1
inner shield
1
1
inner shield
14
14
inner shield
14
14
inner shield
2
25
Y0-
2
25
X0-
15
12
Y0+
15
12
X0+
3
24
Y1-
3
24
X1-
16
11
Y1+
16
11
X1+
4
23
Y2-
4
23
X2-
17
10
Y2+
17
10
X2+
5
22
Yclk-
5
22
Xclk-
18
9
Yclk+
18
9
Xclk+
6
21
Y3-
6
21
X3-
19
8
Y3+
19
8
X3+
7
20
100 ohm
7
20
SerTC+
20
7
terminated
20
7
SerTC-
8
19
Z0-
8
19
SerTFG-
21
6
Z0+
21
6
9
18
Z1-
9
18
CC1-
22
5
Z1+
22
5
CC1+
10
17
Z2-
10
17
CC2+
23
4
Z2+
23
4
CC2-
11
16
Zclk-
11
16
CC3-
24
3
Zclk+
24
3
CC3+
12
15
Z3-
12
15
CC4+
25
2
Z3+
25
2
CC4-
13
13
inner shield
13
13
inner shield
26
26
inner shield
26
26
inner shield
Note
:
*Exterior Overshield is connected to the shells of the connectors on both ends. Unused pairs should be terminated in 100 ohms at
both ends of the cable. Inner shield is connected to signal ground inside camera