32
Piranha4 2K and 4K Camera Color User's Manual
03-032-20180-06
Teledyne DALSA
Step 2. Connect Data, Trigger, and Power Cables
Note
: the use of cables types and lengths other than those specified may result in increased emission or
decreased immunity and performance of the camera.
Figure 22: Input and Output, trigger, and Power Connectors
WARNING! Grounding Instructions
Static electricity can damage electronic components. It’s critical that you discharge any static
electrical charge by touching a grounded surface, such as the metal computer chassis, before
handling the camera hardware.
!
B
B
C
A
Power
+12V to +24V DC Hirose 6-pin
Control & Data
Camera Link 26-pin SDR26 connectors
Status
Diagnostic LED
A
B
C