34
Piranha4 2K and 4K Camera Color User's Manual
03-032-20180-06
Teledyne DALSA
Camera link bit definitions
Signal
Configuration
Remark
CC1
EXSYNC
Keep this signal in
low
status when idle. The exposure time must
not
be
greater than the camera’s allowance—3,000 µs.
CC2
Spare
CC3
Direction
CC4
Spare
Table 6: Camera Control Configuration
For additional Camera Link documentation refer to the Teledyne DALSA Web site’s
Camera Timing
Note: Information on setting up the camera’s AOI can be found here, Area of Interest (AOI) Setup.
RGB 8 bit, CL Base, maximum line rate 20 kHz (4k) and 40 kHz (2k), no AOI and 85 MHz
CL clock
This timing can be used for applications that require line rates only up to 20 kHz and therefore can use
Camera Link Base mode with only one cable.
The RGB output format is compatible with the Camera Link specification for Base RGB. Line rates up to
70 kHz can be achieved by using the Area of Interest (AOI) feature; where the smaller the AOI, the
greater the potential line rate.
Red 1
D0..D7
Blue 1
D0..D7
Green 1
D0..D7
Red 2
D0..D7
Blue 2
D0..D7
Green 2
D0..D7
Red 3
D0..D7
Blue 3
D0..D7
Green 3
D0..D7
Red 4
D0..D7
Green 4
D0..D7
Red 4095
D0..D7
Blue 4095
D0..D7
Green 4095
D0..D7
Red 4096
D0..D7
Blue 4096
D0..D7
Green 4096
D0..D7
Blue 4
D0..D7
CL Port A
CL Port B
CL Port C
CL Clock
Line Valid